Approval/Certificate/Document of Conformity

Page 13 of 24 Report No. 250150-TL6-1
IEC 61984
TRF No. IEC61984C
Testreport-250150-TL6-1.DOCX
VDE File No. 257500-1431-0045/250150
6.14.3
No damage occurs, which could impair normal use.
N/A
THERMAL TEST GROUP C (TABLE 12)
C1
TEMPERATURE RISE TEST: IEC 60512 Test 5A
Test conductor length according Table 7 ............ :
Female part: 250 mm
Male part: direct bridged
Test conductor cross-section .............................. :
1,5 mm²
7.3.7
Mated specimen ................................................. :
See appended tables C1
Test current ........................................................ :
17,5 A
Ambient temperature components .................. :
20°C
Upper limit temperature components .............. :
120°C
6.16
The upper limiting temperature specified for the
specimen is not exceeded
See appended table C1
P
CLIMATIC TEST GROUP D (TABLE 13)
D1
INITIAL MEASUREMENTS (CONTACT RESISTANCE): IEC 60512 Test 2b
Reference value for subsequent measurement .. :
See appended table D1
Test current ........................................................ :
1 A
D2
COLD: IEC 60512 Test 11j
Mated specimen ................................................. :
Test duration ...................................................... :
2 h
Lower temperature limit ...................................... :
-50 °C
VISUAL EXAMINATION: IEC 60512 Test 1a
6.6.3
Sufficient contact pressure through insulation
N/A
6.8 / 6.15
No visual damage, no cracks on insulations parts
likely to impair safety
P
6.18.3
Internal insulation shows no damage likely to impair
safety
P
No damage occurred, which could impair normal
use
P