Approval/Certificate/Document of Conformity

Page 17 of 24 Report No. 250150-TL6-1
IEC 61984
TRF No. IEC61984C
Testreport-250150-TL6-1.DOCX
VDE File No. 257500-1431-0045/250150
B1
TABLE: Initial measurements (Contact resistance)
Test current ...................................................................... :
1 A
Test sample
Contact
1
2
3
PE
1
Thüringische
Weidmüller GmbH
U1 [mV]
1,2
1,1
1,1
--
R1 [m]
1,2
1,1
1,1
--
Contact
1
2
3
PE
2
Thüringische
Weidmüller GmbH
U1 [mV]
1,1
1,1
1,2
--
R1 [m]
1,1
1,1
1,2
--
Contact
1
2
3
PE
3
Weidmüller Interface
(Suzhou)
U1 [mV]
1,2
1,1
1,1
--
R1 [m]
1,2
1,1
1,1
--
supplementary information: SC-SMT + BCF
B4.1
TABLE: Final measurements (Contact resistance)
Test current ......................................................... :
1 A
Number of cycles ................................................ :
25
Condition ............................................................. :
R2max 1,5R1 or
R2max 5 m + R1
Test sample
Contact
1
2
3
PE
1
Thüringische
Weidmüller GmbH
R2max [m]
6,2
6,1
6,1
--
P
U2 [mV]
1,2
1,1
1,1
--
R2 [m]
1,2
1,1
1,1
--
Contact
1
2
3
PE
2
Thüringische
Weidmüller GmbH
R2max [m]
6,1
6,1
6,2
--
P
U2 [mV]
1,1
1,1
1,1
--
R2 [m]
1,1
1,1
1,1
--
Contact
1
2
3
PE
3
Weidmüller Interface
(Suzhou)
R2max [m]
6,2
6,1
6,1
--
P
U2 [mV]
1,1
1,2
1,1
--
R2 [m]
1,1
1,2
1,1
--
supplementary information: SC-SMT + BCF