Approval/Certificate/Document of Conformity

Page 14 of 24 Report No. 250150-TL6-1
IEC 61984
TRF No. IEC61984C
Testreport-250150-TL6-1.DOCX
VDE File No. 257500-1431-0045/250150
D3
DRY HEAT: IEC 60512 Test 11i
Mated specimen .................................................. :
Test duration ...................................................... :
7 days
Upper temperature limit ...................................... :
120 °C
VISUAL EXAMINATION: IEC 60512 Test 1a
6.6.3
Sufficient contact pressure through insulation
N/A
6.8 / 6.15
No visual damage, no cracks on insulations parts
likely to impair safety
P
6.18.3
Internal insulation shows no damage likely to impair
safety
P
No damage occurred, which could impair normal
use
P
D4
PROTECTION AGAINST CORROSION: IEC 60512 Test 11g
7.3.14
Test 1
Flowing mixed gas corrosion according to IEC
60512-11-7, test 11g Method 1 or alternatively
Method 4 (Table 1 of IEC 60512-11-7)). Test
duration is 4 days.
N/A
7.3.14
Test 2
alternative
Sulphur dioxide test with general condensation of
moisture according to ISO 6988 .
Test duration is 24h (1 test cycle)
P
VISUAL EXAMINATION: IEC 60512 Test 1a
6.21
Function guaranteed
P
No damage occurred, which could impair normal
use
P
D5
FINAL MEASUREMENT (CONTACT RESISTANCE): IEC 60512 Test 2b
Test current ........................................................ :
1 A
R2 1,5 R1 or R2 5 m + R1 ................... :
See appended table D5
P
D6
DIELECTRIC STRENGTH: IEC 60512 Test 4a
Mated specimen ................................................. :
See appended table D1
Impulse withstand voltage .................................. :
--
r.m.s. withstand voltage ..................................... :
1,39 kV
6.13
No breakdown or flashover occurred
See appended table D6
P