Approval/Certificate/Document of Conformity

Page 8 of 24 Report No. 250150-TL6-1
IEC 61984
TRF No. IEC61984C
Testreport-250150-TL6-1.DOCX
VDE File No. 257500-1431-0045/250150
b) free connectors in which the terminations are
protected against pull and twisting by mounting
provisions in the end-use product
N/A
DIMENSIONAL EXAMINATION: IEC 60512
6.19
Clearances and creepage distances according to
IEC 60664.
see table 0.2
P
Connector dimensions comply with the DS or
manufacturer’s specification.
N/A
A2
DURABILITY OF MARKING
7.3.2
Test liquid: water
Test piston size 1; force 5 N; 10 cycles
IEC 60068-2-70 Test Xb „Abrasion of marking“
P
VISUAL EXAMINATION: IEC 60512 Test 1a
Visible with the naked eye
P
A3
POLARISATION AND CODING: IEC 60512 / Test [13e]
- For unenclosed connectors (internal connections)
20 N
P
- For enclosed connectors (external connections)
1,5 x mating force, but not higher than 80 N
N/A
6.3
Multipole connector: Contact between protective
earthing contacts and live contacts is not possible
by engagement.
N/A
6.9.1
Multipole connector: Polarisation prevents improper
connection of mating parts.
P
VISUAL EXAMINATION: IEC 60512 Test 1a
No damage likely to impair function
P
A4
PROVISIONS FOR EARTHING
6.5.1
For a CBC the earthing contact is a “first make -
last break” contact.
N/A
7.3.3
No electrical contact indication between earth
contact and the other contacts.
N/A
6.5.4
CONNECTION OF THE PROTECTIVE EARTH CONNECTOR
N/A
VISUAL EXAMINATION: IEC 60512 Test 1a
N/A
Remove any available covers if required.
N/A
6.5.4.1
The protective conductor terminal accepts a
N/A