Approval/Certificate/Document of Conformity

Page 7 of 24 Report No. 250150-TL6-1
IEC 61984
TRF No. IEC61984C
Testreport-250150-TL6-1.DOCX
VDE File No. 257500-1431-0045/250150
MECHANICAL TEST GROUP A (TABLE 10)
A1
VISUAL EXAMINATION: IEC 60512 Test 1a
6.2.2
Marking indelible and easily legible
P
Minimum marking on the connector a) trademark
P
Markings a) trademark and b) type identification on
smallest unit of packaging
P
All other markings (c k) given in the technical
documentation or catalogue of the manufacturer
P
c) Rated current .................................................. :
17,5 A
P
c) Rated voltage ................................................. :
160 V
P
e) Over voltage category .................................... :
1,39 kV
P
f) Pollution degree .............................................. :
3
P
g) Protection degree ........................................... :
IP00
P
h) Range of temperature .................................... :
-50°C up to +120°C
(LLT ULT)
P
i) Type of terminals ............................................. :
Solder termination (PCB)
(male part)
Screw type clamping units
(female parts)
P
j) Connectable conductors ................................. :
0,14 1,5 mm²
Solid and flexible
P
k) Reference to this standard or to the DS
IEC 61984
P
6.2.3
Position for the contacts and protective earthing
contacts clearly indicated.
Marking of protective earthing contacts applies
symbol or “PE”. This requirement is not
necessary for non rewirable connectors.
The definite marking of the
contacts has to be guaranteed
by overprint or the build-in
conditions.
P
6.9.2
Fixing means not used to fix live parts.
P
6.9.3
Termination without damage possible.
P
6.10
CBC has adequate breaking capacity.
N/A
6.11
Free connector: Wires protected against shear and
tensile stress at the termination and secured to
prevent twisting.
N/A
The above requirement does not apply to:
a) free connectors for termination to cables in fixed
mountings (plug connection in the sense of a
detachable connection)
N/A