User Documentation

We reserve the right to make technical changes. Personal support can be found on our website: www.weidmueller.com/contact
PUSH IN connector BVF 7.62 Hybrid
Delivery status:
The clamping units are closed.
Recommended tool:
Screwdriver blade 0.6 x 3.5
Screwdriver blade standard DIN 5264
Connecting exible conductors:
1. Opening clamping unit: Press the screwdriver individually into the appropriate opening until the spring is completely opened and hold the screwdriver in this position.
2. Connecting conductor: Plug in the conductor into the clamping unit up to the end stop.
3. Closing clamping unit: Unlock the spring by removing the screwdriver out of the opening. Make sure that the conductor is inserted
up to the end stop and ensure by gently pulling on the conductors that the clamping unit is securely engaged.
opening for screwdriver
conductor entry
spring clamp