User Documentation

Assembly instructions
PUSH IN connector –
BVF 7.62
OMNIMATE Power – series BVF 7.62
All other technical data can be obtained from the data sheet.
Cables suitable for connection:
Strip the insulation from the cables to a length of approx. 12 mm ± 1 mm. If you are using wire-end ferrule with plastic collars,
strip the cables according to the table below.
min.
cable connection cross-section
max.
cable connection cross-section
Solid (H05(07) V-U) 0.5 mm² 10 mm²
Flexible (H05(07) V-K) 0.5 mm² 10 mm²
with wire-end ferrule according to DIN 46 228/1 1.5 mm² 10 mm²
with wire-end ferrule; with collar DIN 46 228/4 1.5 mm² 6 mm²
AWG 24 8
We recommend using the following wire-end ferrules with plastic collar:
Cable diameter Type Weidmüller color code
Order number
DIN color code
Order number
Stripping length
0.5 mm² H0.5/18 1076980000 1076990000 14 ± 1 mm
0.75 mm² H0.75/18 9025910000 9019060000 14 ± 1 mm
1 mm² H1.0/18 9025930000 9019110000 15 ± 1 mm
1.5 mm² H1.5/18 9019140000 15 ± 1 mm
2.5 mm² H2.5/18 9019170000 9019170000 14 ± 1 mm
4 mm² H4.0/20 9019200000 9019200000 14 ± 1 mm
6 mm² H6.0/20 0533500000 9019220000 14 ± 1 mm
10 mm² H10.0/22 0534200000 9019240000 15 ± 1 mm
We recommend using the following wire-end ferrules without plastic collar:
Cable diameter Type Order number Stripping length
1.5 mm² H1.5/12 9004060000 12 ± 1 mm
2.5 mm² H2.5/12 0186100000 12 ± 1 mm
4 mm² H4.0/12 0244100000 12 ± 1 mm
6 mm² H6.0/12 0191900000 12 ± 1 mm
10 mm² H10.0/12 0282900000 12 ± 1 mm
We reserve the right to make technical changes. Personal support can be found on our website: www.weidmueller.com/contact