User Documentation

We reserve the right to make technical changes. Personal support can be found on our website: www.weidmueller.com/contact
PUSH IN connector design:
Handling:
Recommended tool:
Screwdriver blade 0.4 x 2.5
Screwdriver blade standard DIN 5264
Connecting solid conductors:
1. A stripped solid conductor is simply plugged into the contact point up to the end stop.
Connecting conductors with wire-end ferrule:
1. Stranded conductors with crimped-on wire-end ferrules, with and without plastic collars,
are simply plugged into the contact point up to the end stop.
When plugging-in, an initial resistance (spring clamp) has to be overcome.
Connecting exible conductors:
1. Open the contact point by activating the push-button (slider/pusher).
2. Insert stranded conductors, without crimped-on wire-end ferrules.
3. Remove tool from push-button (slider/pusher).
When connecting or disconnecting the conductors, force of the push-button (slider/pusher) must be max. 40 N.
After connection, the strand/cable has to be checked,
whether the strand is tight and cannot be pulled out again.
Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 16
32758 Detmold, Germany
Phone +49 5231 14-0
Fax +49 5231 14-292083
Email info@weidmueller.com
Web www.weidmueller.com
push-button (slider/pusher)
conductor entry
spring clampend stop
max. 40 N
1.
2.
3.