User Documentation
Operating Instructions
Four-indent crimping tool DigiCrimp® with digital display and wear monitoring
Rev.: 2013-12-02 10 / 10
EN
13 Servicing and maintenance
Make sure that your hand crimper is in a clean and proper state before use. Remove any
crimping residues from between the crimping jaws and contact bushing. Lubricate the joints
regularly with machine lubricant, and protect them from soiling. Make sure that all of the pins
are secured by retaining rings.
Always have the crimper manufacturer or an authorised repair shop repair your four-indent
crimper.
CE-tested according to EMC
EN 55014-1:2006,EN 55014-2:1997+A1:2001, Cat. III
Test conducted by:
CE-LAB GmbH [DAT-P-209/05-00]
Am Hammergrund 1
98693 Ilmenau, Germany
FCC testing
FCC 47 CFR Part 15 Subpart B Class B
Test conducted by:
Herberg Service Plus GmbH [Reg. No. 96997]
European Compliance Laboratory (ECL)
Nordostpark 51, 90411 Nürnberg, Germany
Display Cause Solution
E1
The display shows E1 after correct
recalibration
–Your crimp dies have
reached their limit of wear.
The crimper dies are worn out. Send in
your crimper for repairs.
E2
Calibration or recalibration at a higher
adjustment value than on initial factory
calibration (too much play between the
punch and gauge).
Repeat calibration or recalibration with
the gauge supplied (see 8 or 9).
Repairs and service
As the manufacturer only is authorised for repair and maintenance of the four-indent crimp
tools, please contact the company where you purchased the tool for further assistance.