Brochure/Catalogue

C
C.852737920000
Empty socket
Space-saving, 6.4 mm wide
3 time functions
Empty sockets for electromechanical relays and solid-
state relays
PUSH IN and screw connection
6.4 mm
87.8 mm
89.4 mm
80.8 mm
ON DIP
12345678
6.4 mm
87.8 mm
89.6 mm
80.8 mm
ON
DIP
1
23456
7
8
PUSH IN connection Screw connection
Technical data
Control side
Rated control voltage
Power rating
Status indicator
Repeat accuracy
Basic accuracy
Setting tolerance
Min. pulse duration
Time ranges
Max. reset time after voltage interruption
Load side
Rated switching voltage
Max. switching voltage, AC
Max. switching voltage, DC
Continuous current
General data
Ambient temperature (operational)
Storage temperature
Humidity
Version
Resistance to vibration EN 61812-1
Approvals
Insulation coordinates
Rated voltage
Creepage and clearance distance input – output
Dielectric strength, Input/Output
Impulse withstand voltage
Protection degree
Dimensions
Clamping range (nominal / min. / max.) mm²
Depth x width x height mm
Note
Ordering data
PUSH IN connection
Screw connection
Note
Accessories
Note
TR T 24 V DC 1CO M3 EMPTY
DC-Input
A2
A1
18
NO
COM
15
16
NC
TIMER
CURCUIT
Duo-LED
A1
A2
14 11 12
A1
A2
1
4 1
1
Relay or SSR (not included)
24 V DC ± 20 %
Duo-LED orange: relay output on, Green duo-LED lit: supply voltage on,
Green duo-LED flashes: incorrect configuration, no function
± 1 %
≤ 5% (of scale-end value)
5 %
50 ms
0.01 s - 0.1 s, 0.1 s - 1 s, 1 s - 10 s, 10 s - 100 s
50
250 V AC
250
250 V
10 A
-20 °C...60 °C
-40 °C...85 °C
5-95% relative humidity, T
u
= 40°C, without condensation
Empty socket
CE; cURus; EAC
250 V
≥ 6 mm
4 kV
eff
/ 1 Min.
6 kV (1.2/50 µs)
IP20
PUSH IN connection Screw connection
1.5 / 0.14 / 2.5 1.5 / 0.14 / 2.5
88 / 6.4 / 90 88 / 6.4 / 90
Type Qty. Order No.
TRP T 24VDC 1CO M3 EMPTY 10 2639740000
TRS T 24VDC 1CO M3 EMPTY 10 2639720000
Further approvals and technical data can be found at catalog.weidmueller.com
Accessories: refer to the TERMSERIES Accessories page.
&RQWUROYROWDJH
9'&
%ODQN= FRQWDFWPDWHULDO$J1L
(037<= (PSW\VRFNHWV
7
=
7(506(5,(6
5HOD\
&2= &KDQJHRYHU63'7
0 0XOWLIXQFWLRQDO7LPHU
ZLWKIXQFWLRQV
6= 6FUHZ
3= 386+,1
5
=
5HOD\
7 7LPHU
ON DIP
12345678
Mode
Range
Time
Mode
On Delay
One Shot
Blinker
1
2
Range
10-100s
1-10s
0.1-1s
3
4
10-100ms
Time
0.1
0.2
0.3
5
6
0.4
0.6
0.7
0.8
0.9
7
8
0.5
1.0
= On (DIP-switch turned
to ON-position)
Application range
Timing functions – TERMSERIES TIMER