Brochure/Catalogue

B
B.16 2737920000
1 CO contact
AC / DC / UC coil
'&,QSXW
$
$
$$

12
&20


1&
$
$$

12
&20


1&
$&'&,QSXW
$
$
$$

12
&20


1&
$
$&,QSXW5&)LOWHU
Load side
Rated switching voltage / Continuous current 250 V AC / 16 A
Max. switching voltage, AC
Inrush current 30 A / 4 s
Min. switching power 10 mA @ 10 V, 100 mA @ 5 V
Contact type 1 CO contact (AgNi)
Mechanical service life 30 x 10
6
switching cycles
Max. switching frequency at rated load 0.1 Hz
General data
Ambient temperature (operational) -40 °C...60 °C
Storage temperature -40 °C...85 °C
Humidity 5-95% relative humidity, T
u
= 40°C, without condensation
Approvals CE; cULus; DNVGL; EAC
Insulation coordinates
Rated voltage 300 V
Impulse withstand voltage 6 kV (1.2/50 µs)
Dielectric strength, Input/Output 1.2 kV
eff
/ 5 s
Dielectric strength of neighbouring contacts
Dielectric strength to mounting rail 4 kV
eff
/ 1 Min.
Creepage and clearance distance input – output ≥ 5.5 mm
Overvoltage category III
Pollution degree 2
Dimensions PUSH IN
Screw connection
Clamping range (nominal / min. / max.) mm² 1.5 / 0.14 / 2.5
1.5 / 0.14 / 2.5
Depth x width x height mm 87.8 / 12.8 / 89.4
87.8 / 12.8 / 89.6
Note
Accessories and dimensional drawings: refer to the TERMSERIES Accessories page.
Further approvals and technical data can be found at catalog.weidmueller.com
Switching current [A]
Switching operations
250 esistive loadV AC r
10
7
10
6
10
5
10
4
0
2
4
68
10
12
14
16
Electrical endurance
Switching voltage [V DC]
Switching current [A]
1 contact
300
200
100
50
40
30
20
10
0.10.2 0.51 2510 20
Resistive load
DC load breaking capacity
Applications
Technical data
Space-saving, 12.8mm wide
16A AgNi contact
Internal cross-connection of the output terminals
PUSH IN and screw connection
Universal range
TERMSERIES – relay modules