User Documentation

98
Supported operating systems – Functions
2008050000/03/02-2018
INFOBEREICH
Die Angabe „MatNr/Version/Datum“ bzw. „1234560000/00/MM.YY“ ist als Textvariable deniert
und kann nur auf der „Rueckseite“ editiert werden. Die Textvariable erscheint in allen Doku-
menten dieses Buches, sobald eine Synchronisierung des gesamten Buches(!) durchgeführt
wird. ACHTUNG Die „Rueckseite” muss als Formatquelle(!) ausgewählt sein!
from the device element A.
Copythelistwiththemenuitem“Copylistofdisplayedvalues”intheyoutmenu.Createanewde-
vice element B (see Adding topology) and delete all associated measurement value displays for this
element via “Delete all values from display”. Via the menu item “Insert values from the copied list”,
insert the measurement values previously copied from device element A in device element B.
- “Remove device”
Deletes the device element from the topology page.
- “Activate automatic scaling (all devices)”, “Switch off scaling (all devices)”
The measurement devices for all devices are automatically scaled by ecoExplorer go via their units. If
scaling is deactivated, the measurement value display will be determined by the device.
- “Edit scaling (all devices)”
The group of work and power values are individually adjustable in the scaling. For other values, a se-
lection is made between “No scaling” or “Automatic scaling”.
- “Edit size”
Enables change of display size of the device element by entering pixel width and height. Enables dis-
play to be scaled via the element corners (see Adding topology )
Conguringtopologyelement“image”
• Double-click a previously created and saved topology page in the projects window via the “Topology”
node (see “Add topology page”, “Editing topology page”).
• If the palette window is not visible, open it via the “Window --> Palette” menu.
• Drag the “Image” element from the palette window and drop it in the topology window area.
• Opentheyoutmenubybyrightmouseclickingdesiredelementandselectthemenuitem“Congure”.
NOTE: Anychangestothecongurationareimmediatelyeffective,i.e.theireffectscanbeviewedin
thebackgroundwithouthavingtorstquitthecongurationdialog.
• Select the corresponding device and the desired measurement value for the image.
• Add an image in PNG or JPG format via the “Add image” button. The selected image then appears in the
Images pane. A value ranage initialized with - to + appears under the image. The upper and lower limit of
theselectedvalueisdenedviathevaluerange;theselimitscontrolthedisplayoftheassociatedimage,
i.e. if the selected measurement value is within the value range, then precisely this image is displayed.
Viaaclickwiththerightmousekeyontheimage,acongurationwindowfortheboundaryvaluesofthe
image is opened, by means of which these can be adjusted. An error image is displayed next to the se-
lectionboxesforthedeviceandvaluetype.Thiscanbemodiedviathecorrespondingbuttonbelowor
provided again on the system. Default image with red cross on white background is reset. The error im-
ageisdisplayedifaninvalidboundaryvaluecongurationseriesispresent,noaccesstodeviceispos-
sible or the selected value type is no longer available.
• Invalidimageboundaryvaluecongurations:Ifthevaluerangesofvariousimagesoverlap,depending
on the current value status, no clear assessment can be made about the image display in the topology.
Furthermore, gaps between the individual limit value ranges are not permissible. Further errors can result
from the use of open barriers at the bottom (-) or top (+). Only if there are gaps between the boundary
value ranges can all 3 different elements be used with open interval at the same time, otherwise only
a maximum of 2 of them (in this case the 3rd element closes the gaps). Two equal elements with open
interval (even if the close interval boundary is the same) remain unpermissible. Every invalid state is
acknowledgedwithanerrormessageatthebottomofthecongurationwindowanditisnotpossibleto
savethisconguration.
• Itshouldbenotedthatanychangestothecongurationareimmediatelyeffective,i.e.theireffectscan
beviewedinthebackground.However,invalidcongurationscannotbepermanentlysaved,asinthis