User Documentation

99
Supported operating systems – Functions
2008050000/03/02-2018
INFOBEREICH
Die Angabe „MatNr/Version/Datum“ bzw. „1234560000/00/MM.YY“ ist als Textvariable deniert
und kann nur auf der „Rueckseite“ editiert werden. Die Textvariable erscheint in allen Doku-
menten dieses Buches, sobald eine Synchronisierung des gesamten Buches(!) durchgeführt
wird. ACHTUNG Die „Rueckseite” muss als Formatquelle(!) ausgewählt sein!
casetheFinishbuttonisconcealedandonlywaytoquitthecongurationwindowisviatheresetbutton
or corrections must be made previously.
• Add another image via the “Add image” button. The value range of this image is then initialized with mi-
nusinnity(-)toplusinnity(+).Asthevaluerangeofbothimagesoverlap,anerrormessageappears
and saving is not possible.
• Thencongurethevaluerangeoftheloadedimagesviatherightmousekey.Clickthecorrespondingim-
ageandselecttheitem“BoundsCong”intheyoutmenu.Setthecorrespondingvaluerangeviathe
inputeldsfortheupperandlowerboundary.Ifnospecicboundaryisentered,thisinputisreadas“in-
nity”().Theimagevaluerangesmaynotoverlapandmaynothavegaps!Theimagesareautomatically
sorted in rising order from the lower boundary value. It thus does not play a role in which order you insert
theimages.Ifnoerrorsarepresent,thecongurationdialogcanbesavedvia“Exit”.The“Revertand
Exit” button enables the changes to be reset.
• Example:
- Select a device and set the measurement value to “Effective power L1”.
- Add an image via the “Add image” button (the value range is from “-” to “+”)..
- Add another image (the value range is from “-” to “+”)..
- Thecongurationindicatesanerrorasthevaluerangesoverlap.
- Setthevaluerangeintheyoutmenuviaitem“BoundsCong”byrightclickingthecorresponding
image (image 1). Set the upper limit to a sensible value (x1).
- Proceedasabovetocongurethevaluerangeforthesecondimage.Setthelowerlimittothevaluex1
(see above, upper boundary of Image 1).
- If the measurement value size now changes the value range, then the image also changes. The
change is directly visible in the topology window.
- Quitthecongurationdialogwith“Exit”.
• The image to be shown in the event of an error (e.g. “Connection to device lost” or “Measurement value
no longer available”) can be edited via the “Select Error Image” button.
• Byclickingtheimageelement,determinewiththeitems“forward”or“back”intheyoutmenu,thevisible
orderoftheelements(see“Conguringdevicetopologyelement”).
Anelementcanberemovedfromthetopologypagevia“Deleteelement”intheyoutmenufortheelement.
Conguringtopologyelement“Onlinevalue”
• Using the menu item “Window --> Value type(s)”, open the value tree window.
• Select a device in the project window. The online values in the value tree window then show the meas-
urement values for this device.
• Open the desired measurement value type in the node structure for the online values (e.g. “Effective volt-
age”).
- With the left mousekey or alternatively with <Ctrl> or <Shift>, select several of these and also drag it/
them with the left mousekey to the topology window.
• Opentheyoutmenubyrightclickingdesiredelement(measurementvalue)andselectthedesiredfunc-
tion:
- “To front”, “To back”
If two elements are superimposed or overlap, then the visible sequence can be changed via these set-
tings.
- “Title”