Approval/Certificate/Document of Conformity

NF X 70100-1: 2006 & NF X 70-100-2: 2006
Test Details
Purpose of test To
determine the performance of specimens of a material when they are
subjected to the conditions of test specified in NFX 70 - 100: 2006 “Analysis Of
Gaseous effluents, Part 1: Methods for analysing gases produced by thermal
degradation and Part 2: Tubular furnace thermal degradation method”.
The tests were performed in accordance with the procedure specified in NFX 70
100-1: 2006 and NF X 70-100-2: 2006 at a temperature of 600°C and this report
should be read in conjunction with that Standard.
Scope of test NFX 70-100-1: 2006 and NF X 70-100-2: 2006
specifies a method of test for
carrying out quantitative analysis of certain gases produced under specified
conditions of thermal degradation in the presence of air.
Fire test study
group/EGOLF
Certain aspect
s of some fire test specifications are open to different
interpretations. The Fire Test Study Group and EGOLF have identified a
number of such areas and have agreed Resolutions which define common
agreement of interpretations between fire test laboratories which are members
of the Groups. Where such Resolutions are applicable to this test they have
been followed.
Instruction to test The test was conducted on the 23
rd
May 2016 at the request of the original
sponsor of the test.
Provision of test
specimens
The specimens were supplied by the original sponsor of the test. Exova
Warringtonfire was not involved in any selection or sampling procedure.
Conditioning of
specimens
The specimens were received on the 9
th
May 2016.
Prior to test the specimens were conditioned to constant mass at temperatures of
23 ± 2°C and a relative humidity of 50 ± 5% RH, for a minimum period of 48
hours prior to testing.
Document No.: Additional Test Report
386712
Page No.: 5 of 11
Author: T. Mort Issue Date: 28
th
July 2017
Client: Weidmüller Interface
GmbH & Co. KG
Issue No.: 1