Approval/Certificate/Document of Conformity

NF X 70100-1: 2006 & NF X 70-100-2: 2006
Observations
In the case of each specimen the test duration was 40 minutes and the volume of the gas sampled was
80 litres. In each case the air was circulated using a suction method.
In the case of each specimen a nominally 1g sample was obtained which was representative of the
substance or material as used in practice.
Specimen
No.
1 2 3 1 2 3 1 2 3 1 2 3
Gases
HCN
HCl / HBr / SO
2
HF
NO
x
Mass (g)
1.0000
1.0000
0.9970
1.0020
0.9990
1.0010
1.0010
N/A
N/A
1.0000
1.0020
1.0020
Mass loss
(g)
0.5420 0.5460 0.5610 0.5380 0.5480 0.5510 0.5470 N/A N/A 0.5500 0.5700 0.5660
Mass loss
(%)
54.20 54.60 56.27 53.69 54.85 55.04 54.65 N/A N/A 55.00 56.89 56.49
Ignition
time
(min:secs)
(if
applicable)
00:50 00:50 00:59 00:50 00:46 00:52 01:02 N/A N/A 00:51 00:53 00:45
Extinction
time
(min:secs)
(if
applicable)
02:12 02:17 02:14 02:10 02:16 02:05 02:20 N/A N/A 02:08 02:14 02:18
Key:
N/A = Not applicable
Document No.: Additional Test Report
386712
Page No.: 10 of 11
Author: T. Mort Issue Date: 28
th
July 2017
Client: Weidmüller Interface
GmbH & Co. KG