Approval/Certificate/Document of Conformity

NF X 70100-1: 2006 & NF X 70-100-2: 2006
Executive Summary
Objective
To determine the performance of the following product when tested in accordance
with the procedure specified in NF X 70-100-1: 2006 & NF X 70-100-2: 2006.
Generic Description
Product reference
Thickness
Density
Crosslinked ethylene vinyl
acetate (EVA) heat shrink tubing
“HSS-HF & “HS-HF”
0.4-1mm
1.4g/ml³
Please see page 5 of this test report for the full description of the product tested
Test Sponsor
Weidmüller Interface GmbH & Co. KG, Klingenbergstraße 16, 32758 Detmold,
Germany
Summary of Test
Results:
When tested in accordance with the procedure specified in NF X 70100-1: 2006
& NF X 70-100-2: 2006 at a temperature of 600°C, the following results were
obtained:
C.I.T (NF F 16-101 (withdrawn)) = 4.24
R value (BS 6853 Annex B.1(withdrawn) / LUL S1085 Attachment A.1)) =
0.32
C.I.T
NLP
(BS EN 45545-2:2013+A1:2015) = 0.06
Date of Test
23
rd
May 2016
This test report is additional to that issued as 364996 dated the 31
st
May 2016 and has been issued at the
request of the sponsor. The original test report remains valid and is not replaced by this additional test report.
The product referred to in the original report and this additional test report has not been re-tested since the
original test and neither has a technical review of the original test report resulting in any technical changes
been carried out.
The original product reference of the product has been removed and the reference “HSS-HF” & “HS-HF” has
been inserted and the original sponsor name and address details have been removed and those of Weidmüller
Interface GmbH & Co. KG” have been inserted. The sponsor of the test has stated that the material described in
this additional report is identical to the material which was tested. Both the original and the alternative trade
names of the product and the original and alternative sponsor details have been documented and the
documentation is maintained in the confidential file covering this investigation.
Document No.: Additional Test Report
386712
Page No.: 2 of 11
Author: T. Mort Issue Date: 28
th
July 2017
Client: Weidmüller Interface
GmbH & Co. KG
Issue No.: 1