Brochure/Catalogue

Media converter - Value Line
Industrial Media Converter (10/100BaseT (X) to 100BaseFX)
10/100BaseT(X) auto-negotiation and auto-MDI/MDI-X
Link Fault Pass-Through (LFP)
Power failure, port break alarm by relay output
Redundant power inputs
Designed for hazardous locations (Zone 2)
Technical data
Technology
Standards IEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT (X) and 100BaseFX
Interfaces
Fibre Ports 100BaseFX (SC/ST-duplex connection)
RJ45 ports 10/100BaseT(X)
DIP Switches 100BaseFX Full/Half duplex selection,
Port fault alarm
Alarm Contact One relay output with current carrying capacity of 1 A at 24 V DC
Specication optical ber
Transceiver Type
100Base FX
Multi-Mode Single-Mode
Fiber Cable Type OM1
50/125 μm
G.652
800 MHz*km
Typical Distance 4 km 5 km 40 km
Wave-
length
Typical (nm) 1300 1310
TX Range (nm) 1260 to 1360 1280 to 1340
RX Range (nm) 1100 to 1600 1100 to 1600
Optical
Power
TX Range (dBm) -10 to -20 0 to -5
RX Range (dBm) -3 to -32 -3 to -34
Link-Budget (dB) 12 29
Dispersion Penalty (dB) 3 1
Note: When connecting a single-mode ber transceiver over a short distance, we recommend using an
attenuator to prevent the transceiver from being damaged by excessive optical power.
Power Requirements
Input Voltage 24 V DC (12 to 48 V DC), two redundant inputs
Current consumption 0.16 A at 24 V
Connection 1 removable 6-pole terminal block
Overload Current Protection 1.1 A
Reverse Polarity Protection Present
Technical data
Housing Metal, IP30 protection
Dimensions (W x H x D) 53.6 x 135 x 105 mm (2.11 x 5.31 x 4.13 in)
Weight 630 g
Installation DIN-Rail, wall (with optional mounting kit)
Environmental Limits
Operating temperature Standard Models: 0 to 60 °C (32 to 140 °F)
Wide Temp. Models: -40 to 75 °C (-40 to 167 °F)
Operating Humidity 5 to 95 % (non-condensing)
Storage Temperature -40 to 85 °C (-40 to 185 °F)
Approvals
Security UL 508
EMC EN 55032/24
CISPR 32, FCC Part 15B Class A
IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m
IEC 61000-4-4 EFT: Power: 2 kV; Signal: 2 kV
IEC 61000-4-5 Surge: Power: 1 kV; Signal: 1 kV
IEC 61000-4-6 CS: 3 V
IEC 61000-4-8
Hazardous Location UL/cUL Class1, Division 2, Groups A, B, C, and D,
ATEX Zone 2 Ex nA nC IIC T4 Gc
Maritime DNV-GL
Freefall IEC60068-2-32
Shock IEC60068-2-27
Vibration IEC60068-2-6
MTBF (mean time between failures)
Time 401,000 hrs
Database MIL-HDBK-217F: GB 25 °C
Warranty
Warranty Period 5 years
Ordering data
Version Type Operating
Temperature
Order No.
1 * RJ45, 1 * SC-Multimode IE-MC-VL-1TX-1SC
IE-MC-VLT-1TX-1SC
0 to +60 °C
-40 to +75 °C
1241400000
1286880000
1 * RJ45, 1 * ST-Multimode IE-MC-VL-1TX-1ST
IE-MC-VLT-1TX-1ST
0 to +60 °C
-40 to +75 °C
1241410000
1286890000
1 * RJ45, 1 * SC-Singlemode IE-MC-VL-1TX-1SCS
IE-MC-VLT-1TX-1SCS
0 to +60 °C
-40 to +75 °C
1241420000
1286900000
Accessories
Type Order No.
19" Rack Mounting Kit RM-KIT 1241440000
Wall mounting kit IE-WALLMOUNT-KIT-46MM 1504440000
T \ %
PPLQ
PPLQ
PPLQ
,(0&9/6HULHV
PPLQ
D
Media converter and protocol gateways
D.32596860000