User Documentation

IE-CS(T)-2TX-xRS232/485 Web Console Configuration
5-10
To modify the serial settings for a specific port, click Port X (X=1 or 2) under Serial Settings.
Port alias
Setting Factory Default Necessity
1 to 15 characters
(E.g., PLC-No.1)
None Optional
“Port alias” is included to allow easy identification of the serial devices that are connected to the
IE-CS(T)-2TX-xRS232/485’s serial ports.
Serial Parameters
ATTENTION
Check the serial communication parameters in your Serial Device’s user’s manual. You should set up the
IE-CS(T)-2TX-xRS232/485’s serial parameters with the same communication parameters being used by your
serial devices.
Baudrate
Setting Factory Default Necessity
50 bps to 921.6 Kbps 115.2 Kbps Required
Data bits
Setting Factory Default Necessity
5, 6, 7, 8 8 Required
When a user sets the Data bits to 5 bits, the Stop bits setting will automatically change to 1.5 bits.
Stop bits
Setting Factory Default Necessity
1, 1.5, 2 1 Required
Stop bits will be set to 1.5 when the Data bits is set to 5 bits.
Parity
Setting Factory Default Necessity
None, Even, Odd,
Space, Mark
None Required