User Documentation

IE-CS(T)-2TX-xRS232/485 Web Console Configuration
5-13
Allow driver control
Setting Factory Default Necessity
No or Yes No Optional
If “Max connection” is greater than 1, IE-CS(T)-2TX-xRS232/485 will ignore the driver control commands from
all connected hosts. However, if you set “Allow driver control” to “Yes,” control commands will be accepted.
Note: Since the IE-CS(T)-2TX-xRS232/485 may get configuration changes from multiple hosts, the most
recent command it receives will take precedence.
Packing length
Setting Factory Default Necessity
0 to 1024 0 Optional
Default = 0, The Delimiter Process will be followed, regardless of the length of the data packet. If the data
length (in bytes) matches the configured value, the data will be forced out. The data length can be configured
for 0 to 1024 bytes. Set to 0 if you do not need to limit the length.
Delimiter 1
Setting Factory Default Necessity
00 to FF (hex) None Optional
Delimiter 2
Setting Factory Default Necessity
00 to FF (hex) None Optional
Once the IE-CS(T)-2TX-xRS232/485 receives both delimiters through its serial port, it immediately packs all
data currently in its buffer and sends it to the IE-CS(T)-2TX-xRS232/485’s Ethernet port.
ATTENTION
Delimiter 2 is optional. If left blank, then Delimiter 1 alone trips the clearing of the buffer. If the size of the
serial data received is greater than 1 KB, the IE-CS(T)-2TX-xRS232/485
will automatically pack the data and
send it to its Ethernet port. However, to use the delimiter function, you must at least enable Delimiter 1. If
Delimiter 1 is left blank and Delimiter 2 is enabled, the delimiter function will not work properly.
Delimiter process
Setting Factory Default Necessity
Do nothing, Delimiter +
1, Delimiter + 2, Strip
Delimiter
Do Nothing Optional
[Delimiter + 1] or [Delimiter + 2]: The data will be transmitted when an additional byte (for Delimiter +1), or
an additional 2 bytes (for Delimiter +2) of data is received after receiving the Delimiter.
[Strip Delimiter]: When the Delimiter is received, the Delimiter is deleted (i.e., stripped), and the remaining
data will be transmitted.
[Do nothing]: The data will be transmitted when the Delimiter is received.
Force transmit
Setting Factory Default Necessity
0 to 65535 ms 0 ms Optional
0: Disable the force transmit timeout.
1 to 65535: Forces the IE-CS(T)-2TX-xRS232/485’s TCP/IP protocol software to try to pack serial data received
during the specified time into the same data frame.
This parameter defines the time interval during which the IE-CS(T)-2TX-xRS232/485 fetches the serial data
from its internal buffer. If data is incoming through the serial port, the IE-CS(T)-2TX-xRS232/485 stores the