User Documentation

IE-CS(T)-2TX-xRS232/485 Web Console Configuration
5-33
SNMP Trap Server
SNMP trap server IP or domain name
Setting Factory Default Necessity
IP address or Domain
Name
None Optional
Event Type
Cold start
This refers to starting the system from power off (contrast this with warm start). When performing a cold start,
the IE-CS(T)-2TX-xRS232/485 will automatically issue an Auto warning message by e-mail, or send an SNMP
trap after booting up.
Warm start
This refers to restarting the computer without turning the power off. When performing a warm start, the
IE-CS(T)-2TX-xRS232/485 will automatically send an e-mail, or send an SNMP trap after rebooting.
Authentication failure
The user inputs a wrong password from the Console or Administrator. When authentication failure occurs, the
IE-CS(T)-2TX-xRS232/485 will immediately send an e-mail or send an SNMP trap.
IP address changed
The user has changed the IE-CS(T)-2TX-xRS232/485’s IP address. When the IP address changes, the
IE-CS(T)-2TX-xRS232/485 will send an e-mail with the new IP address before the IE-CS(T)-2TX-xRS232/485
reboots. If the IE-CS(T)-2TX-xRS232/485 is unable to send an e-mail message to the mail server within 15
seconds, the IE-CS(T)-2TX-xRS232/485 will reboot anyway, and abort the e-mail auto warning.
Password changed
The user has changed the IE-CS(T)-2TX-xRS232/485’s password. When the password changes, the
IE-CS(T)-2TX-xRS232/485 will send an e-mail with the password changed notice before the
IE-CS(T)-2TX-xRS232/485. If the the IE-CS(T)-2TX-xRS232/485 is unable to send an e-mail message to the
mail server within 15 seconds, the IE-CS(T)-2TX-xRS232/485 will reboot anyway, and abort the e-mail auto
warning.