3.9.2 OTDR measurement
Alongside the attenuation measurement procedure (insertion loss measurement
procedure), the OTDR (Optical Time Domain Reectometer) measurement
procedure can also be used to measure bre-optic cables. This can be used to
determine faulty points in the bre-optic cable.
To do so, the device transmits a signal into the bre-optic cable via a forerun
bre. An overrun bre is also tted downstream of the section. Forerun and
overrun bres appropriate to the measurement cable should be used for OTDR
measurements in order to minimise measurement errors.
Parts of the signal are reected at connection points in the course of the bre-
optic measurement cable or interference points. The device now measures the
strength of the reected part of the signal and the time between the signal being
sent and the reection being received. From the measurement results, you can
tell the location of defect and its inuence.
Figure3.6:PrincipleoftheOTDRmeasurement