Brochure/Catalogue
Media converter - Value Line
Industrial Media Converter (10/100BaseT (X) to 100BaseFX)
• 10/100BaseT(X) auto-negotiation and auto-MDI/MDI-X
• Link Fault Pass-Through (LFP)
• Power failure, port break alarm by relay output
• Redundant power inputs
• Designed for hazardous locations (Zone 2)
Technical data
Technology
Standards IEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT (X) and 100BaseFX
Interfaces
Fibre Ports 100BaseFX (SC/ST-duplex connection)
RJ45 ports 10/100BaseT(X)
DIP Switches 100BaseFX Full/Half duplex selection,
Port fault alarm
Alarm Contact One relay output with current carrying capacity of 1 A at 24 V DC
Specication optical ber
Transceiver Type
100Base FX
Multi-Mode Single-Mode
Fiber Cable Type OM1
50/125 μm
G.652
800 MHz*km
Typical Distance 4 km 5 km 40 km
Wave-
length
Typical (nm) 1300 1310
TX Range (nm) 1260 to 1360 1280 to 1340
RX Range (nm) 1100 to 1600 1100 to 1600
Optical
Power
TX Range (dBm) -10 to -20 0 to -5
RX Range (dBm) -3 to -32 -3 to -34
Link-Budget (dB) 12 29
Dispersion Penalty (dB) 3 1
Note: When connecting a single-mode ber transceiver over a short distance, we recommend using an
attenuator to prevent the transceiver from being damaged by excessive optical power.
Power Requirements
Input Voltage 24 V DC (12 to 48 V DC), two redundant inputs
Current consumption 0.16 A at 24 V
Connection 1 removable 6-pole terminal block
Overload Current Protection 1.1 A
Reverse Polarity Protection Present
Technical data
Housing Metal, IP30 protection
Dimensions (W x H x D) 53.6 x 135 x 105 mm (2.11 x 5.31 x 4.13 in)
Weight 630 g
Installation DIN-Rail, wall (with optional mounting kit)
Environmental Limits
Operating temperature Standard Models: 0 to 60 °C (32 to 140 °F)
Wide Temp. Models: -40 to 75 °C (-40 to 167 °F)
Operating Humidity 5 to 95 % (non-condensing)
Storage Temperature -40 to 85 °C (-40 to 185 °F)
Approvals
Security UL 508
EMC EN 55032/24
CISPR 32, FCC Part 15B Class A
IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m
IEC 61000-4-4 EFT: Power: 2 kV; Signal: 2 kV
IEC 61000-4-5 Surge: Power: 1 kV; Signal: 1 kV
IEC 61000-4-6 CS: 3 V
IEC 61000-4-8
Hazardous Location UL/cUL Class1, Division 2, Groups A, B, C, and D,
ATEX Zone 2 Ex nA nC IIC T4 Gc
Maritime DNV-GL
Freefall IEC60068-2-32
Shock IEC60068-2-27
Vibration IEC60068-2-6
MTBF (mean time between failures)
Time 401,000 hrs
Database MIL-HDBK-217F: GB 25 °C
Warranty
Warranty Period 5 years
Ordering data
Version Type Operating
Temperature
Order No.
1 * RJ45, 1 * SC-Multimode IE-MC-VL-1TX-1SC
IE-MC-VLT-1TX-1SC
0 to +60 °C
-40 to +75 °C
1241400000
1286880000
1 * RJ45, 1 * ST-Multimode IE-MC-VL-1TX-1ST
IE-MC-VLT-1TX-1ST
0 to +60 °C
-40 to +75 °C
1241410000
1286890000
1 * RJ45, 1 * SC-Singlemode IE-MC-VL-1TX-1SCS
IE-MC-VLT-1TX-1SCS
0 to +60 °C
-40 to +75 °C
1241420000
1286900000
Accessories
Type Order No.
19" Rack Mounting Kit RM-KIT 1241440000
Wall mounting kit IE-WALLMOUNT-KIT-46MM 1504440000
T \ %
PPLQ
PPLQ
PPLQ
,(0&9/6HULHV
PPLQ
D
Media converter and protocol gateways
D.32596860000