User Documentation

User Manual Managed Switches
112
NOTE: Auto warning e-mail messages will be sent through an authentication protected
SMTP server that supports the CRAM-MD5, LOGIN, and PAIN methods of SASL
(Simple Authentication and Security Layer) authentication mechanism.
We strongly recommend not entering your Account Name and Account Password if auto
warning e-mail messages can be delivered without using an authentication mechanism.
3.10.4 Configuring Relay Warnings
The Auto Relay Warning function uses relay output to alert the user when certain user-configured
events take place. There are two basic steps required to set up the Relay Warning function:
Configure Relay Event Types
Select the desired Event types from the Console or Web Browser Event type page (a description of
each event type is given later in the Relay Warning Events Settings subsection).
Activate your settings
After completing the configuration procedure you will need to activate your Weidmüller switch’s
Relay Event Types.
Configuring Relay Warning Events Settings
Event Types can be divided into two basic groups: System Events and Port Events. System Events
are related to the overall function of the switch, whereas Port Events are related to the activity of a
specific port.
The Weidmüller switch supports two relay outputs. You can configure which relay output is related to
which events, which helps administrators identify the importance of the different events.
System Events
Warning Relay output is triggered when…