User Documentation

User Manual Managed Switches
118
DHCP Option 82
Enable Option 82
Setting
Description
Factory
Default
Enable or Disable
Enable or disable the DHCP Option 82 function.
Disable
Type
Setting
Description
Factory
Default
IP
Uses the switch’s IP address as the remote ID sub.
IP
MAC
Uses the switch’s MAC address as the remote ID sub.
IP
Client-ID
Uses a combination of the switch’s MAC address and
IP address as the remote ID sub.
IP
Other
Uses the user-designated ID sub.
IP
Value
Setting
Description
Factory
Default
Max. 12
characters
Displays the value that was set. Complete this field if
type is set to Other.
Switch IP
address
Display
Setting
Description
Factory Default
read-only
The actual hexadecimal value configured in the
DHCP server for the Remote-ID. This value is
automatically generated according to the Value field.
Users cannot modify it.
COA87FFD
DHCP Function Table
Option 82
Setting
Description
Factory
Default
Enable or
Disable
Enable or disable the DHCP Option 82 function for this
port.
Disable