User Documentation
User Manual Managed Switches
148
connected
Monitor PROFINET I/O Cyclic Data
Weidmüller switches provide PROFINET I/O cyclic data
for real-time monitoring. In side bar you can see Device
data and Port data.
To monitor Device data, use Drag & Drop to pull the Device data onto slot 1. Right-click on slot 1,
then select Monitor/Modify.
Use Monitor to check the input data value. In this
dialog, select Monitor and then, you can see the
status value of each address. Please refer to the
PROFINET Cyclic I/O data table to see the
meaning of each bit.
For example, address 0.2 is set to Bit 1. It represents
Power 2 status of the switch. 1 means Power 2 is
present and Green will be displayed in the section
Status value.
Refer to the PROFINET Cyclic I/O data table at the beginning of this chapter for the meanings of
each address.