User Documentation

User Manual Managed Switches
42
(Max. 32 users)
Database as the authentication database.
Radius
Select this option to set an external RADIUS server as
the authentication database. The authentication
mechanism is EAP-MD5.
Local
Radius, Local
Select this option to make using an external RADIUS
server as the authentication database the first priority.
The authentication mechanism is EAP-MD5 The first
priority is to set the Local User Database as the
authentication database.
Local
Radius Server
Setting
Description
Factory
Default
IP address or
domain name
The IP address or domain name of the RADIUS server
local host
Server Port
Setting
Description
Factory
Default
Numerical
The UDP port of the RADIUS server
1812
Shared Key
Setting
Description
Factory
Default
alphanumeric
(Max. 40
characters)
A key to be shared between the external RADIUS
server and the Weidmüller switch. Both ends must be
configured to use the same key.
None
Re-Auth
Setting
Description
Factory
Default
Enable/Disable
Select enable to require re-authentication of the client
after a preset time period of no activity has elapsed.
Disable
Re-Auth Period
Setting
Description
Factory
Default
Numerical
(60 to 65535 sec)
Specify how frequently the end stations need to
reenter usernames and passwords in order to stay
connected.
3600
802.1X
Setting
Description
Factory
Default
Enable/Disable
Checkmark the checkbox under the 802.1X column to
Disable