User Documentation

User Manual Managed Switches
52
Max. 30
characters
Specifies the community string to authenticate the
SNMP agent for read-only access. The SNMP agent
will access all objects with read-only permissions using
this community string.
Public
V1, V2c Write/Read Community
Setting
Description
Factory
Default
Max. 30
characters
Specifies the community string to authenticate the
SNMP agent for read/write access. The SNMP server
will access all objects with read/write permissions
using this community string.
Private
For SNMP V3, there are two levels of privileges for different accounts to access the Weidmüller
switch. Admin privilege allows access and authorization to read and write the MIB file. User privilege
allows reading the MIB file only.
Admin Auth. Type (for SNMP V1, V2c, V3 and V3 only)
Setting
Description
Factory
Default
No-Auth
Allows the admin account to access objects without
authentication.
No
MD5-Auth
Authentication will be based on the HMAC-MD5
algorithms. 8-character passwords are the minimum
requirement for authentication.
No
SHA-Auth
Authentication will be based on the HMAC-SHA
algorithms. 8-character passwords are the minimum
requirement for authentication.
No
Admin Data Encryption Key (for SNMP V1, V2c, V3, and V3 only)
Setting
Description
Factory
Default
Enable
Enables data encryption using the specified data
encryption key (between 8 and 30 characters).
No
Disable
Specifies that data will not be encrypted.
No
User Auth. Type (for SNMP V1, V2c, V3 and V3 only)
Setting
Description
Factory
Default
No-Auth
Allows the admin account and user account to
access objects without authentication.
No
MD5-Auth
Authentication will be based on the HMAC-MD5
algorithms. 8-character passwords are the minimum
requirement for authentication.
No