User Documentation

User Manual Managed Switches
56
Port Setting
Enable
Setting
Description
Factory
Default
Checked
Allows data and power transmission through
the port
Enable
Unchecked
Immediately shuts off port access
Enable
Power Limit
Setting
Description
Factory
Default
Auto
The amount of power assigned is determined
according to the class that is read from the
powered device.
Auto
Manual
The user can set the power limit value that
indicates the maximum amount of power
available to the port.
Auto
The PoE Ethernet switch can monitor PD working status via its IP conditions. If the PD fails, the
switch will not receive a PD response after the defined period, and the authentication process is
restarted. This is an excellent function to ensure your network reliability and reduce management
burden.
PD Failure Check
Setting
Description
Factory
Default
Checked
Enables the PD Failure Check function.
Auto
Unchecked
Disables the PD Failure Check function.
Auto
IP
Setting
Description
Factory
Default
Max. 15
Characters
Enter the IP for the PD
None
Period
Setting
Description
Factory
Default
Max. 5
Characters
Enter the time span for IP checking period
None