Approval/Certificate/Document of Conformity

[13]
Schedule
[14] TYPE EXAMINATION CERTIFICATE No.
DEMKO 11 ATEX 150191X Rev. 4
00-IC-F0060-1 – Issue 14.0
This certificate may only be reproduced in its entirety and without any change, schedule included. Page 3 of 3
Electrical data
Model
Electrical Rating
Relay Output
Protection Method
Series IE-SW-VL16-16TX
12-48VDC, 0.6A,
24VDC, 1A, Resistive
nA nC
Series IE-SW-VL16T-16TX
12-48VDC, 0.6A,
24VDC, 1A, Resistive
nA nC
Series IE-SW-PL16M-16TX
12-48VDC, 1.6A,
24VDC, 1A, Resistive
nA nC
Series IE-SW-PL16MT-16TX
12-48VDC, 1.6A,
24VDC, 1A, Resistive
nA nC
Series IE-SW-PL18M-2GC-16TX
12-48VDC, 1.6A,
24VDC, 1A, Resistive
nA nC
Series IE-SW-PL18MT-2GC-16TX
12-48VDC, 1.6A,
24VDC, 1A, Resistive
nA nC
For alternate construction
IE-SW-VL16-16TX, IE-SW-VL16T-
16TX, IE-SW-VL16-14TX-2SC, IE-
SW-VL16T-14TX-2SC, IE-SW-
VL16-14TX-2ST, IE-SW-VL16T-
14TX-2ST
12/24/48 VDC, 0.86/0.4/0.2A,
Class 2
or
12-48Vdc, 0.86-0.2A, Class 2 or
12-48Vdc, 0.86A max., Class 2
or
12Vdc, 0.86A, Class 2 or
24Vdc, 0.4A, Class 2 or 48Vdc,
0.2A, Class 2
24VDC, 1A, Resistive
nA nC
Routine tests:
No routine tests are necessary.
[16] Descriptive Documents
The scheduled drawings are listed in the report no. provided under item no. [ 8 ] on page 1 of this Type Examination Certificate.
[17] Special Conditions of Use:
The Ethernet Communication Devices are to be mounted in an ATEX-Certified tool-accessible IP54 enclosure and used in an area of
not more than pollution degree 2 as defined by EN 60664-1.
Provisions shall be made, either in the equipment or external to the equipment, to provide the transient protection device to be set at
a level not exceeding 140% of the peak rated voltage.
[18] Essential Health and Safety Requirements
The Essential Health and Safety Requirements (EHSRs) covered by the standards listed at item 9.
Additional information
The trademark will be used as the company identifier on the marking label.