Approval/Certificate/Document of Conformity

IECEx Certificate of Conformity
Annexe
IECEx ITA 14.0013X
Issue No.:
02
This form is identified as QMA-HAE-08-710 Issued 2014-05-19 Page 1 of 3
Description (continued from certificate):
The enclosures are populated with push button, lamps, switches, and potentiometers consisting of:
Electrical elements (including lamps/switches and potentiometers) and
Actuating elements (including push buttons, emergency stops and lamp covers)
The assembled small control stations are suitable for:
Hazardous gas areas - protection class IIC Ex d e (increased safety and flameproof
components); or
Hazardous dust areas - protection class IIIC Ex tb (protection by enclosure)
Refer to AU/ITA/ExTR15.0011/00 for details regarding the component certificate assessments of
components certified to older standards.
Temperature Ratings:
Ex
Code
Minimum
Wire Size
Current
Rating
Maximum Ambient
Temperature
T Rating
Cable Thermal
Class
Ex d e
IIC
1.5mm
2
10A
40°C
T6
70
55°C
T5
90
16A
40°C
T5
90
55°C
T4
105
2.5mm
2
16A
40°C
T6
70
55°C
T5
90
Ex tb
IIIC
1.5mm
2
10A
40°C
T80°C
70
55°C
T85°C
90
16A
40°C
T85°C
90
55°C
T105°C
105
2.5mm
2
16A
40°C
T80°C
70
55°C
T100°C
90
IP Ratings:
The IP rating of the equipment will be the least protection rating for water and dust from all external
components.
.