cable glands – Nickel–plated Brass – Ex e, Ex d, IP68 for armoured and non-armoured cables
'
6:
/
/
'
7KUHDG
All-purpose cable gland for cables and lines with single-wire armouring, metal-foil
armouring and braided armouring. Non-armoured cables and lines can also be connected.
Technical data
Material Brass, nickel-plated
O-Ring / Seal insert Silicone / Silicone
Temperature range -60 °C...180 °C
Degree of protection IP66, IP68 - 2.5 bar
Water depth 25 m (30 Min.)
Type of armouring Single-wire armouring, Metal foil armouring, Braided armouring
Marking ATEX: II 2G, Ex db IIC Gb, Ex eb IIC Gb, II 1D, Ex ta IIIC Da, IECEx: Ex db IIC Gb, Ex eb IIC Gb, Ex ta IIIC Da
Certificate no. (ATEX / IECEx / EAC) SIRA 05ATEX1285X / IECEx SIR 05.0067X / RUC-DE.IT08.B.00594
Note
Length "L" depends on the cable diameter used.
Cable glands made of brass with natural surface are available in the online catalogue (catalog.weidmueller.com).
Ordering data
Type Thread D1 outer cable Ø D2 inner cable Ø Cable armour L/L1 SW SUHB Qty. Order No.
metric, nickel-plated brass
KDSU M20 BS O NI 1 G16 M 20 6.7-10.3 3.40-8.40 0.1-1.25 78 / 16 24 L24 20 0930001221
KDSU M20 BS O NI 2 G16 M 20 9-13.5 3.40-8.40 0.1-1.25 78 / 16 24 L24 20 0930001222
KDSU M20 BS O NI 1 G20 M 20 12-17.6 9.40-14.00 0.1-1.25 78 / 16 30 EL30 20 0930021221
KDSU M20 BS O NI 2 G20 M 20 15.5-21.1 9.40-14.00 0.1-1.25 78 / 16 30 EL30 20 0930021222
KDSU M20 BS O NI 1 G20S M 20 9.4-12.5 7.20-11.70 0.1-1.25 78 / 16 24 L24 20 0930011223
KDSU M20 BS O NI 2 G20S M 20 11.5-16 7.20-11.70 0.1-1.25 78 / 16 24 L24 20 0930011224
KDSU M25 BS O NI 1 G25 M 25 16.8-23.9 13.50-20.00 0.1-1.6 90 / 16 38 EL38 20 0930031221
KDSU M25 BS O NI 2 G25 M 25 20.3-27.4 13.50-20.00 0.1-1.6 90 / 16 38 EL38 1 0930031222
KDSU M32 BS O NI 1 G32 M 32 23.2-30.5 19.50-26.30 0.1-2 105 / 16 46 EL46 10 0930041221
KDSU M32 BS O NI 2 G32 M 32 26.7-34 19.50-26.30 0.1-2 105 / 16 46 EL46 10 0930041222
KDSU M40 BS O NI 1 G40 M 40 28.6-36.2 23.00-32.20 0.1-2 113 / 16 55 EL55 10 1136990000
KDSU M40 BS O NI 2 G40 M 40 33-40.6 23.00-32.20 0.1-2 113 / 16 55 EL55 10 0930051222
KDSU M50 BS O NI 1 G50 M 50 41.1-48.5 33.10-44.10 0.1-2.5 125 / 16 65 EL65 1 1137010000
KDSU M50 BS O NI 2 G50 M 50 45.7-53.2 33.10-44.10 0.1-2.5 125 / 16 65 EL65 1 1137020000
KDSU M50 BS O NI 1 G50S M 50 34.8-42.4 28.10-38.20 0.1-2.5 125 / 16 65 EL65 1 1137000000
KDSU M50 BS O NI 2 G50S M 50 39.4-46.7 28.10-38.20 0.1-2.5 125 / 16 65 EL65 1 0930061224
KDSU M63 BS O NI 1 G63 M 63 53.8-61.2 46.70-56.00 0.1-2.5 125 / 19 80 EL80 1 1137050000
KDSU M63 BS O NI 2 G63 M 63 58.4-65.8 46.70-56.00 0.1-2.5 125 / 19 80 EL80 1 0930091222
KDSU M63 BS O NI 1 G63S M 63 47.5-54.8 39.20-50.10 0.1-2.5 125 / 19 80 EL80 1 1137030000
KDSU M63 BS O NI 2 G63S M 63 52.1-59.5 39.20-50.10 0.1-2.5 125 / 19 80 EL80 1 1137040000
KDSU M75 BS O NI 1 G75 M 75 66.5-73.4 58.00-68.00 0.1-2.5 131 / 19 90 EL90 1 1137080000
KDSU M75 BS O NI 2 G75 M 75 71.1-78 58.00-68.00 0.1-2.5 131 / 19 90 EL90 1 1137090000
KDSU M75 BS O NI 1 G75S M 75 60.2-68 52.10-62.00 0.1-2.5 131 / 19 90 EL90 1 1137060000
KDSU M75 BS O NI 2 G75S M 75 64.8-72.2 52.10-62.00 0.1-2.5 131 / 19 90 EL90 1 1137070000
Note
All cable glands have a thread pitch of 1.5mm.
In the case of Ex d applications, the inner threads used for cable glands must meet the requirements of section 5.3 of EN/IEC 60079-1. In the screwed in position, at least 5 threads must be engaged.
If the cable glands are installed in non-metallic Ex e connection equipment, these must be connected to the protective earth of the system.
The connection cable must be laid securely and inflexibly to rule out tensile stress.
Installation specifications and tightening torques can be found in the installation instructions. For further information please use our online catalogue: catalog.weidmueller.com.