Approval/Certificate/Document of Conformity

SCHEDULE
EU-TYPE EXAMINATION CERTIFICATE Sira 05ATEX1288X
Issue 5
This certificate and its schedules may only be
reproduced in its entirety and without change
CSA Group Netherlands B.V.
Utrechseweg 310,
6812 AR, Arnhem Netherlands
DQD 544.11 Rev 2018-04-20 Page 7 of 9
Entry
thread
size
Gland
size
Max. Ø
over cores
(mm)
Max.
number
of cores
Max. inner
sheath
(mm)
Outer sheath
(standard) (mm)
Braid dia.
Min.
Max.
Min.
Max.
M20 x 1.5
20S
10.4
8
11.7
9.4
0.15
0.15
0.35
M20 x 1.5
20
12.5
14
14.0
12.0
0.15
0.15
0.5
The lusion of a brass continuity washer within the KUB, KB, KBOS and KSB cable glands ranges
enabling them to be used with lead inner sheathed cables; glands with this modification are
identified with a ‘2’ in their type number.
Variation 2 - This variation introduced the following changes:
i. Following appropriate re-assessment to demonstrate compliance with the requirements of the
EN 60079 series of standards, the documents originally listed in section 9, EN 50014:1997
(amendments 1 and 2), EN 50018:2000 and EN 50281-1-1:1998, were replaced by those currently
listed, the markings in section 12 were updated accordingly.
Variation 3 - This variation introduced the following change:
i. The UK manufacturing site was removed from the certificate.
Variation 4 - This variation introduced the following changes:
i. To allow the ambient range to be extended from -60°C to +85°C to -60°C to +135°C.
ii. The introduction of a new protection coding ‘Ex e IIC’ is recognised, the descriptions have been
amended to reflect the introduction of this new coding.
iii. An assessment to the latest standards was conducted, reference to EN 61241-0 and EN 61241-0
was removed and IEC 60079-31:2008 introduced.
iv. The KUB Range can now be used as a Reversible Line Bushing.
v. An rease of the IP rating degree of protection to IPX8 at 100 m for 7 days.
vi. To allow the maximum number of cores permitted to be reased, description was modified
accordingly.
vii. The assessment of the dust marking against EPL ‘Da’; as a result the marking at section 12 has
been amended accordingly.
viii. The KB Range can now be used as a Line Bushing for terminating flying leads or for the direct
inter-connection of associated enclosures.
ix. Following appropriate reassessment, EN 60079-0:2009 has been replaced by EN 60079-0:2012,
the marking has been amended to remove the IP rating as a result of this assessment.
x. Following appropriate reassessment, IEC 60079-31:2008 has been replaced by EN 60079-31:2009,
the Special conditions for Safe Use have been amended to reflect this assessment.
Variation 5 - This variation introduced the following changes:
i. To modify/introduce the following changes to type KUB and KBOS and KSB and KB Cable Glands:
KUB and KBOS and KSB and KB standard trade M100 / 4” NPT duplicated information was
removed from the General Arrangement Drawing
KSB and KB, gland sizes 50S, 63S and 75S were introduced.
KSB, gland size 75, metric M75, has reduced and replaced the standard NPT female connection
thread size from 3” NPT to 2 ½” NPT. Reducing the alternative female connection thread size
from 3” NPSM to 2 ½” NPSM