Brochure/Catalogue

C
C.552028840000
Lightning and surge protection
for low voltage supply
Type II surge arrester for use in photovoltaic
applications
Pluggable arrester
Suitable for protecting DC systems as Type II arrester
Encapsulated, non-blow-out arrester
Tested in accordance with EN 50539-11
Pluggable arresters
Suitable for use in accordance with IEC 60364-7-712 /
EN 50539-12
Usage if the separation distance can be observed
Technical data
Max. continuous voltage, Uc (DC)
Discharge current I
max
(8/20µs) wire-PE
Discharge current I
n
(8/20µs) wire-PE
PV voltage, acc. to IEC 60364-7-712
Leakage current at U
n
Response time
Optical function display
Design
Colour
Ambient temperature (operational)
Storage temperature
Connection according to IEC 947-7-1
Solid
Stranded
Stripping length
Tightening torque
Technical data - photovoltaic
Maximum continuous operating voltage UCPV mode +/-, -/PE, +/PE
Protection level U
p
mode (+/-)
Protection level U
p
mode(+/PE)
Protection level U
p
mode (-/PE)
Conditions and requirements
Short-circuit resistance I
SCPV
PV system voltage, max. U
cpv
Approvals
Approvals
Standards
Dimensions / Signalling contact info
Clamping range (nominal / min. / max.) mm²
Height x width x depth mm
Signalling contact
Note
Ordering data
without remote signalling contact
with remote signalling contact (R)
Note
Accessories
Note
VPU II 2 PV/R 600 V
Photovoltaics
U U
OK
CHANGE
OK
CHANGE
11 1412
PE
PE
600 V
40 kA
20 kA
< 600 V
30 µA
≤ 25 ns
green = OK; red = arrester is defective - replace
Installation housing; 2TE, Insta IP 20
Black, Arrester red
-40 °C...70 °C
-40 °C...80 °C
1.5...16 mm²
1.5...50 mm²
15 mm
2...3 Nm
600 V DC
≤ 4.4 kV
≤ 2.2 kV
≤ 2.2 kV
EN 50539-11
200 A
600 V
CE; EAC
EN 50539-11
no remote sig. contact with remote signalling (R)
16 / 1.5 16 / 1.5
94 / 35.6 / 69 106 / 35.6 / 69
No 250 V 1 A 1 NC
Type Qty. Order No.
VPU II 2 PV 600V DC 1 1351340000
VPU II 2 R PV 600V DC 1 1351370000
Pluggable spare arrester VPU II 0 PV 600 V-1351320000
VPU II 3 PV/R 1200 V
Photovoltaics
U U
OK CHANGE OK CHANGE
U
OK CHANGE
1200 V
40 kA
20 kA
< 1200 V
30 µA
≤ 25 ns
green = OK; red = arrester is defective - replace
Installation housing; 3TE, Insta IP 20
Black, Arrester red
-40 °C...70 °C
-40 °C...80 °C
1.5...16 mm²
1.5...50 mm²
15 mm
2...3 Nm
1200 V DC
≤ 4.4 kV
≤ 4.4 kV
≤ 4.4 kV
EN 50539-11
200 A
1200 V
CE; EAC
EN 50539-11
no remote sig. contact with remote signalling (R)
16 / 1.5 16 / 1.5
94 / 53.4 / 69 106 / 53.4 / 69
No 250 V 1 A 1 NC
Type Qty. Order No.
VPU II 3 PV 1200V DC 1 1351420000
VPU II 3 R PV 1200V DC 1 1351440000
Pluggable spare arrester VPU II 0 PV 1,200 V-1351390000
Lightning and surge protection for photovoltaic systems on the DC side