User Documentation

-21-
No.PF※※-OMP0002-H
Outline of Settings [Measurement mode]
Power is supplied
The output will not operate for 3 seconds after supplying power.
The identification code of the product is displayed.
[Measurement mode]
Measurement mode is the condition where the flow is detected and displayed, and the
switch function is operating.
This is the basic mode; other modes should be selected for set-point changes and other
function settings.
Press the
button
once.
Press the
button for
2 seconds or
longer.
Flow Setting
[3 step setting mode]
(Refer to page 22.)
Function Setting
[Function selection mode]
(Refer to page 24.)
Other Functions
(Refer to page 54.)
: The outputs will continue to operate during setting.
: If a button operation is not performed for 30 seconds during the setting, the display will flash. (This is to prevent the setting from
remaining incomplete if, for instance, an operator were to leave during setting)
: 3 step setting mode and Function selection mode are reflected on each other.