Brochure/Catalogue

TERMSERIES PLC’S system cables – Selection tables
PLC ABB S800
8-channel solution
PLC Cables Connection TERMSERIES adapter
Input/Output cards Standard
TERMSERIES adapter (Relay 6.4 mm)
TERMSERIES
adapter
Inputs or outputs
with relays
Manufacturer
code
Number/
Type of channels
Order No. Qty.
Screw
connection
Tension-clamp
connection
Order No. Qty. Order No. Qty.
DI
DI810 16 DI
B)
7789641xxx 1 1463550000 1
1123000000
16
1123120000
DI814 16 DI
A)
7789641xxx 1 1463550000 1
1123000000
16
1123120000
DI830 16 DI
B)
7789641xxx 1 1463550000 1
1123000000
16
1123120000
DI840 16 DI
B)
7789641xxx 1 1463550000 1
1123000000
16
1123120000
DI880 16 DI
B)
7789641xxx 1 1463550000 1
1123000000
16
1123120000
DO
DO810 16 DO
A)
7789641xxx 1 1463550000 1
1122770000
16
1122880000
DO814 16 DO
B)
7789641xxx 1 1463550000 1
1122780000
16
1122890000
DO840 16 DO
A
7789641xxx 1 1463550000 1
1122770000
16
1122880000
DO880 16 DO
A)
7789641xxx 1 1463550000 1
1122770000
16
1122880000
Note
A) The TERMSERIES adapter switch, should be positioned on the "-" side.
B) The TERMSERIES adapter switch, should be positioned on the "+" side.
The adapters should receive power from an external supply.
The last 3 digits of the cable code indicates its length in decimeters. For example, if the code ends in 100, the cable would be 10 m long.
The relays indicated in the table are chosen for 24 V DC control voltage. For digital input cards these can be replaced by TERMSERIES relays with control voltages from 5 V DC to 230 V AC.
PLC Cables Connection TERMSERIES adapter TERMSERIES adapter
Input/Output cards Standard
TERMSERIES adapter (Relay 6.4 mm) TERMSERIES adapter (Relay 12.8 mm)
TERMSERIES
adapter
Inputs or outputs
with relays
TERMSERIES
adapter
Inputs or outputs
with relays
Manufacturer
code
Number/
Type of channels
Order No. Qty.
Screw
connection
Tension-clamp
connection
Order No. Qty. Order No. Qty. Order No. Qty. Order No. Qty.
DI
DI810 16 DI
B)
1512410xxx 1 1463520000 2
1123000000
16 1463540000 2
1123730000
16
1123120000 1123850000
DI814 16 DI
A)
1512410xxx 1 1463520000 2
1123000000
16 1463540000 2
1123730000
16
1123120000 1123850000
DI830 16 DI
B)
1512410xxx 1 1463520000 2
1123000000
16 1463540000 2
1123730000
16
1123120000 1123850000
DI840 16 DI
B)
1512410xxx 1 1463520000 2
1123000000
16 1463540000 2
1123730000
16
1123120000 1123850000
DI880 16 DI
B)
1512410xxx 1 1463520000 2
1123000000
16 1463540000 2
1123730000
16
1123120000 1123850000
DO
DO810 16 DO
A)
1512410xxx 1 1463520000 2
1122770000
16 1463540000 2
1123490000
16
1122880000 1123610000
DO814 16 DO
B)
1512410xxx 1 1463520000 2
1122780000
16 1463540000 2
1123500000
16
1122890000 1123620000
DO815 8 DO
A)
1512390xxx 1 1463520000 1
1122770000
8 1463540000 1
1123490000
8
1122880000 1123610000
DO840 16 DO
A)
1512410xxx 1 1463520000 2
1122770000
16 1463540000 2
1123490000
16
1122880000 1123610000
DO880 16 DO
A)
1512410xxx 1 1463520000 2
1122770000
16 1463540000 2
1123490000
16
1122880000 1123610000
Note
A) The TERMSERIES adapter switch, should be positioned on the "-" side.
B) The TERMSERIES adapter switch, should be positioned on the "+" side.
The adapters should receive power from an external supply.
The last 3 digits of the cable code indicates its length in decimeters. For example, if the code ends in 100, the cable would be 10 m long.
The relays indicated in the table are chosen for 24 V DC control voltage. For digital input cards these can be replaced by TERMSERIES relays with control voltages from 5 V DC to 230 V AC.
PLC ABB S800
16-channel solution
E
Isolated Interfaces and solutions for general
applications
E.192690170000