Brochure/Catalogue

Klippon
®
KDSU Cable Glands
Structure of the part description
Order key [Type] [a] [b] [c] [d] [e] [f] [ggg]
Example article description KDSU M20 B S O SC 1 G16
Meaning [Type] = Gland type (KDSU)
[a] = Entry thread (M20-M75)
[b] = Material (B = brass)
[c] = Seal material (S = Silicone, N = Neoprene)
[d] = Continuity for lead sheath (L = yes, O = no)
[e] = Plating (SC = self-coloured, NI = Nickel)
[f] = Cable outer sheath (1 = Reduced, 2 = Standard)
[ggg] = Gland size (G16-G75)
A
D
C
B
Note Refer to page D.22 Selection Guide Klippon
®
Cable Glands to determine the suitable order number
Dimensions
Gland Seal Range
Gland Size Entry
thread
Entry
thread
Length
Max
Outer
Diameter
Max
Length
Cable
Inner Sheath
[C]
Cable
Outer Sheath
[D]
Armour
Acceptance
Range
Shroud
Size
Standard
[f] = 2
Reduced
[f] = 1[ggg] [a] [B] [A]
Min Max Min Max Min Max
G16 M20 16 28.0 78.0 3.4 8.4 9.0 13.5 6.7 10.3 0.15 - 1.25 L24
G20S M20 16 28.0 78.0 7.2 11.7 11.5 16.0 9.4 12.5 0.15 - 1.25 L24
G20 M20 16 33.0 78.0 9.4 14.0 15.5 21.1 12.0 17.6 0.15 - 1.25 EL30
G25 M25 16 41.4 90.0 13.5 20.0 20.3 27.4 16.8 23.9 0.15 - 1.60 EL38
G32 M32 16 50.6 105.0 19.5 26.3 26.7 34.0 23.2 30.5 0.15 - 2.00 EL46
G40 M40 16 60.5 113.0 23.0 32.2 33.0 40.6 28.6 36.2 0.20 - 2.00 EL55
G50S M50 16 71.5 125.0 28.1 38.2 39.4 46.7 34.8 42.4 0.30 - 2.50 EL65
G50 M50 16 71.5 125.0 33.1 44.1 45.7 53.2 41.1 48.5 0.30 - 2.50 EL65
G63S M63 19 88.0 125.0 39.2 50.1 52.1 59.5 47.5 54.8 0.30 - 2.50 EL80
G63 M63 19 88.0 125.0 46.7 56.0 58.4 65.8 53.8 61.2 0.30 - 2.50 EL80
G75S M75 19 99.0 131.0 52.1 62.0 64.8 72.2 60.2 68.0 0.30 - 2.50 EL90
G75 M75 19 99.0 131.0 58.0 68.0 71.1 78.0 66.5 73.4 0.30 - 2.50 EL90
Dimensions in mm
Important Notes
The gland size does not necessarily equate to the entry thread size.
In some cases several gland sizes can be chosen due to overlapping inner as well as outer cable diameters. Due to the wide range of armoured cables available, it is necessary to select the correct clamping range.
This is achieved by taking the inner and outer clamping range values to determine the best t (as close as possible to the Min/Max values average).
All cable glands have a 1.5 mm pitch.
For Flameproof Ex d applications the female thread into which the gland is to be tted must achieve an engagement of at least 5 full threads in compliance with clause 5.3 of EN/IEC 60079-1.
Where KDSU glands are tted into non-metallic Increased Safety Ex e enclosures they must be included within the earth circuit of the system.
Fully assembly instructions are supplied with the glands. The instructions must be read prior to installation and adhered to in full.
When the gland is used to terminate un-armoured cables, the gland is suitable only for xed installation.
The KDSU type glands provide a universal armour clamp for steel wire, steel tape, screened or braided
cables. An electrical bond between the cable armour and the gland is ensured. The gland can also be used to
terminate un-armoured cables. In addition, the gland is tted with two separate seals to seal the outer and
inner cable insulation.
When choosing the gland with a neoprene sealing a temperature range from -35 °C to +90 °C will be
achieved. Whereas the gland with silicone sealing ensures a temperature range from -60 °C to +180 °C.
With both sealing materials an IP rating of IP68 to 25 metres (30 min. at 2.5 bar) is maintained. The KDSU is
approved for explosion protection type of pressure-resistant encapsulation Ex d and increased safety Ex e.
D
D.172712630000
Cable entries