Structure of the part description
Order key [Type] [a] [b] [c] [d] [e] [f] [ggg]
Example article description KSG M20 B S O SC 2 G16
Meaning [Type] = Gland type (KSG)
[a] = Entry thread (M20-M90)
[b] = Material (B = brass)
[c] = Seal material (S = Silicone, N = Neoprene)
[d] = Continuity for lead sheath (L = yes, O = no)
[e] = Plating (SC = self-coloured, NI = Nickel)
[f] = Cable outer sheath (2 = Standard)
[ggg] = Gland size (G16-G90)
A
D
B
Note Refer to page D.22 Selection Guide Klippon
®
Cable Glands to determine the suitable order number
Dimensions
Gland Seal Range
Gland Size Entry thread Entry
thread
Length
Max
Outer
Diameter
Max
Length
Cable
Outer Sheath
[D]
Shroud
Size
[ggg] [a] [B] [A]
Standard
[f] = 2
Min Max
G16 M20 16 28.0 33.0 4.0 8.4 L24
G20S M20 16 28.0 33.0 7.2 11.7 L24
G20 M20 16 33.0 33.0 9.6 14.0 L30
G25 M25 16 41.4 33.0 13.5 20.0 L38
G32 M32 16 50.6 33.0 19.5 26.3 L46
G40 M40 16 60.5 37.0 23.0 32.2 L55
G50S M50 16 71.5 37.0 28.2 38.2 L65
G50 M50 16 71.5 37.0 33.2 44.1 L65
G63S M63 19 88.0 37.0 39.3 50.1 L80
G63 M63 19 88.0 37.0 46.7 56.0 L80
G75S M75 19 99.0 37.0 52.3 62.0 L90
G75 M75 19 99.0 37.0 58.1 69.0 L90
Dimensions in mm
Important Notes
The gland size does not necessarily equate to the entry thread size.
In some cases several gland sizes can be chosen due to overlapping inner as well as outer cable diameters. Due to the wide range of armoured cables available, it is necessary to select the correct clamping range.
This is achieved by taking the inner and outer clamping range values to determine the best t (as close as possible to the Min/Max values average).
All cable glands have a 1.5 mm pitch.
For Flameproof Ex d applications the female thread into which the gland is to be tted must achieve an engagement of at least 5 full threads in compliance with clause 5.3 of EN/IEC 60079-1.
Where KSG glands are tted into non-metallic Increased Safety Ex e enclosures they must be included within the earth circuit of the system.
Fully assembly instructions are supplied with the glands. The instructions must be read prior to installation and adhered to in full.
When the gland is used to terminate un-armoured cables, the gland is suitable only for xed installation.
The KSG gland is designed to terminate un-armoured cables. When choosing the gland with a neoprene
sealing a temperature range from -35 °C to +90 °C will be achieved, whereas the gland with silicone sealing
ensures a temperature range from -60 °C to +180 °C. With both sealing materials an IP rating of IP66 and
IP68 to 25 metres (30 min. at 2.5 bar) is maintained. The KSG type gland is approved for Flameproof Ex d and