Cable entries
D.272712630000
Klippon
®
cable glands – Nickel–plated Brass – Ex e, Ex d, IP68 for armoured and non-armoured cables
'
6:
/
/
'
7KUHDG
All-purpose cable gland for cables and lines with single-wire armouring, metal-foil
armouring and braided armouring. Non-armoured cables and lines can also be connected.
Technical data
Material Brass, nickel-plated
O-Ring / Seal insert NBR / CR
Temperature range -35 °C...90 °C
Degree of protection IP66, IP68 - 2.5 bar
Water depth 25 m (30 Min.)
Type of armouring Single-wire armouring, Metal foil armouring, Braided armouring
Marking ATEX: II 2G, Ex db IIC Gb, Ex eb IIC Gb, II 1D, Ex ta IIIC Da, IECEx: Ex db IIC Gb, Ex eb IIC Gb, Ex ta IIIC Da
Certificate no. (ATEX / IECEx / EAC) SIRA 05ATEX1285X / IECEx SIR 05.0067X / RUC-DE.IT08.B.00594
Note
Length "L" depends on the cable diameter used.
Cable glands made of brass with natural surface are available in the online catalogue (catalog.weidmueller.com).
Ordering data
Type Thread D1 outer cable Ø D2 inner cable Ø Cable armour L/L1 SW SUHB Qty. Order No.
metric, nickel-plated brass
KDSU M20 BN O NI 1 G16 M 20 6.7-10.3 3.40-8.40 0.1-1.25 78 / 16 24 L24 20 1083280000
KDSU M20 BN O NI 2 G16 M 20 9-13.5 3.40-8.40 0.1-1.25 78 / 16 24 L24 20 1911380000
KDSU M20 BN O NI 1 G20S M 20 9.4-12.5 7.20-11.70 0.1-1.25 78 / 16 24 L24 20 1083290000
KDSU M20 BN O NI 2 G20S M 20 11.5-16 7.20-11.70 0.1-1.25 78 / 16 24 L24 20 1911390000
KDSU M20 BN O NI 1 G20 M 20 12-17.6 9.40-14.00 0.1-1.25 78 / 16 30 EL30 20 1083320000
KDSU M20 BN O NI 2 G20 M 20 15.5-21.1 9.40-14.00 0.1-1.25 78 / 16 30 EL30 20 1911400000
KDSU M25 BN O NI 1 G25 M 25 16.8-23.9 13.50-20.00 0.1-1.6 90 / 16 38 EL38 20 1083330000
KDSU M25 BN O NI 2 G25 M 25 20.3-27.4 13.50-20.00 0.1-1.6 90 / 16 38 EL38 20 1911420000
KDSU M32 BN O NI 1 G32 M 32 23.2-30.5 19.50-26.30 0.1-2 105 / 16 46 EL46 10 1083340000
KDSU M32 BN O NI 2 G32 M 32 26.7-34 19.50-26.30 0.1-2 105 / 16 46 EL46 10 1911430000
KDSU M40 BN O NI 1 G40 M 40 28.6-36.2 23.00-32.20 0.1-2 113 / 16 55 EL55 10 1083350000
KDSU M40 BN O NI 2 G40 M 40 33-40.6 23.00-32.20 0.1-2 113 / 16 55 EL55 10 1911440000
KDSU M50 BN O NI 1 G50 M 50 41.1-48.5 33.10-44.10 0.1-2.5 125 / 16 65 EL65 1 1083370000
KDSU M50 BN O NI 2 G50 M 50 45.7-53.2 33.10-44.10 0.1-2.5 125 / 16 65 EL65 1 1911460000
KDSU M50 BN O NI 1 G50S M 50 34.8-42.4 28.10-38.20 0.1-2.5 125 / 16 65 EL65 1 1083360000
KDSU M50 BN O NI 2 G50S M 50 39.4-46.7 28.10-38.20 0.1-2.5 125 / 16 65 EL65 1 1911450000
KDSU M63 BN O NI 1 G63S M 63 47.5-54.8 39.20-50.10 0.1-2.5 125 / 19 80 EL80 1 1083380000
KDSU M63 BN O NI 2 G63S M 63 52.1-59.5 39.20-50.10 0.1-2.5 125 / 19 80 EL80 1 1911480000
KDSU M63 BN O NI 1 G63 M 63 53.8-61.2 46.70-56.00 0.1-2.5 125 / 16 80 EL80 1 1083390000
KDSU M63 BN O NI 2 G63 M 63 58.4-65.8 46.70-56.00 0.1-2.5 125 / 19 80 EL80 1 1911490000
KDSU M75 BN O NI 1 G75S M 75 60.2-68 52.10-62.00 0.1-2.5 131 / 19 90 EL90 1 1083400000
KDSU M75 BN O NI 2 G75S M 75 64.8-72.2 52.10-62.00 0.1-2.5 131 / 19 90 EL90 1 1083410000
KDSU M75 BN O NI 1 G75 M 75 66.5-73.4 58.00-68.00 0.1-2.5 131 / 19 90 EL90 1 1083420000
KDSU M75 BN O NI 2 G75 M 75 71.1-78 58.00-68.00 0.1-2.5 131 / 19 90 EL90 1 1083430000
Note
All cable glands have a thread pitch of 1.5mm.
In the case of Ex d applications, the inner threads used for cable glands must meet the requirements of section 5.3 of EN/IEC 60079-1. In the screwed in position, at least 5 threads must be engaged.
If the cable glands are installed in non-metallic Ex e connection equipment, these must be connected to the protective earth of the system.
The connection cable must be laid securely and inflexibly to rule out tensile stress.
Installation specifications and tightening torques can be found in the installation instructions. For further information please use our online catalogue: catalog.weidmueller.com.
Ex-cable glands – Brass