Approval/Certificate/Document of Conformity

Page 18 of 23 Report No. 249955-TL6-1
IEC 61984
TRF No. IEC61984C
Testreport-249955-TL6-1.DOCX
VDE File No. 257500-1431-0044/249955
C1
TABLE: Temperature rise test
Ambient temperature (°C) ................................... :
20 °C
Thermocouple Locations
Test current
(A)
Upper temperature
limit (ULT) (°C)
Temperature
measured (°C)
Female part
27
100
86,0
P
Female part
83,5
P
Male part
98,9
P
Male part
94,2
P
supplementary information: BLT 5.08HC + SL-SMT 5.08HC
D1
TABLE: Initial measurements (Contact resistance)
Test current ................................................................................. :
1 A
Test sample
Contact
1
2
3
PE
1
U1 [mV]
0,69
0,64
0,74
--
R1 [m]
0,69
0,64
0,74
--
supplementary information: BLT 5.08HC + SL-SMT 5.08HC
D5
TABLE: Final measurements (Contact resistance)
Test current ...............................................................................:
1 A
Condition ...................................................................................:
R2max 1,5R1 or
R2max 5 m + R1
Test sample
Contact
1
2
3
PE
1
R2max [m]
5,69
5,64
5,74
--
P
U2 [mV]
0,6
0,6
0,8
--
R2 [m]
0,6
0,6
0,8
--
supplementary information: BLT 5.08HC + SL-SMT 5.08HC
D6
TABLE: Dielectric strength (mated specimen)
Test voltage applied between:
a) Impulse withstand
voltage applied
b) r.m.s withstand
voltage applied
Breakdown / flashover
(Yes/No)
Contact - Contact
--
2,21 kV
No
Contact - Earth
--
--
--
Contact - Surface
--
--
--
supplementary information: BLT 5.08HC + SL-SMT 5.08HC