Approval/Certificate/Document of Conformity

Job Id:
262.1
-
021947
-
4
Certificate No: TAA000016R
Revision No: 4
Form code: TA 251 Revision: 2016-12
www.dnvgl.com
Page 4 of 7
Place of manufacture
Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 16
32758 Detmold
Germany
Zollner Electronic AG
Untergschwandt 3
94371 Rattenberg
Germany
S C ZES Zollner Electronic SRL
Parc Industrial SUD NR FN
440247 Satu Mare
Romania
Approval Conditions
The Type Approval covers hardware listed under Product description.
When the hardware is used in applications to be classed by DNV GL, documentation for the actual
application is to be submitted for approval by the manufacturer of the application system in each case.
Reference is made to DNV GL RU SHIP Pt.4 Ch.9 Sec. 1.
Product certificate
If specified in the Rules, ref. Pt.4 Ch.9 Sec.1, the control and monitoring system in which the above
listed hardware is used shall be delivered with a product certificate. For each such delivery the
certification test is to be performed at the manufacturer of the application system before the system is
shipped to the yard. The test shall be done according to an approved test program. After the certification
the clause for application software control will be put into force.
Clause for application software control
All changes in software are to be recorded as long as the system is in use on board. The records of all
changes are to be forwarded to DNV for evaluation and approval. Major changes in the software are to
be approved before being installed in the computer.
Application/Limitation
Corrosion test (salt mist) was not carried out. Compliance with the IEC 60945 in this regard to be considered
case-by-case.
Type Approval documentation
Laboratory test plan remote I/O-system UR20 “u-remote” (Index 1 / 31.08.2016)
Prüfaufbau DUT1_DUT2_Maritim_EMV (Revision 2 / 30.08.2016)
Prüfaufbau UR20 DUT3_DUT4 maritime Zulassungen ENV (05.12.2016)
Prüfaufbau UR20 DUT3_DUT4 maritime Zulassungen EMC (05.12.2016)
Prüfaufbau DUT5_DUT6 Project Template 2.4 ENV (28.03.2017)
Prüfaufbau DUT5_DUT6 Project Template 2.4 EMC (28.03.2017)
Protocol-Performance test DUT1&DUT2 LO16-00907 (19.09.2016)
Protocol-Performance test DUT5&DUT6 LO17-00364 (04.04.2017)
Protocol Conducted Emission test DUT5&DUT6 (04.04.2017)
Test report Weidmüller LAB20918E (28.03.2017)
Test report Weidmüller LAB20971E (28.03.2017)
Test report Weidmüller LAB20972E (28.03.2017)
Test report Weidmüller LAB18426 (02.12.2014)
Test report RS Schwarze no. 2016142a (10.11.2016)
Test report RS Schwarze no. 2016142b (14.11.2016)
Test report RS Schwarze no. 2016142c (14.11.2016)
Test report Weidmüller LAB21033E (09.05.2017)