o Under normal operating conditions the temperature rise of the terminal blocks is max 40 K, measured with the max permitted
rated current. Due to the above mentioned the terminal blocks may be used in apparatus of temperature classes T6…T1 as long
as the terminal block ambient temperature range is not exceeded as shown below. No part of terminal block must exceed 110 °C
under any condition.
T6 (- 60°C ≤ Tamb ≤ +40 °C)
T5 (- 60°C ≤ Tamb ≤ +55 °C)
T4 (- 60°C ≤ Tamb ≤ +70 °C)
o When using the types WDU and WPE with other terminal blocks series or sizes or accessories, the requirements for clearance
and creepage distances according to table 1 of EN 60079-7 must be observed. Regarding the use of covers, cross-connectors
and end brackets the instructions of the manufacturer must be followed.
o For terminal jumper accessories current ratings and the resistances across the terminals please refer to the table under “types &
electrical rating” above. Details on creepage and clearance values and the required torque values are in the respective “Notice to
installers”.
o The terminal can be used with either one or two wires into either side of the terminal. When two wires are used they must be of the
same type, and of equal sizes. No other wire sizes or types than the ones specified in instructions must be used. The terminal
blocks must either be mounted next to another block of the same type and size or with an end plate.
o If smaller conductor cross sections than the rated conductor cross sections are used, then the corresponding lower current shall
be stated in the Certificate of the complete apparatus
o Unused terminals shall be tightened.
[18] Essential Health and Safety Requirements
The Essential Health and Safety Requirements (EHSRs) covered by the standards listed at item 9.
Additional information
The trademark will be used as the company identifier on the marking label.
The manufacturer shall inform the notified body concerning all modifications to the technical documentation as described in Annex III to