Datasheet

Data sheet
ACT20M
ACT20M-UI-AO-S
Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 26
D-32758 Detmold
Germany
Fon: +49 5231 14-0
Fax: +49 5231 14-292083
www.weidmueller.com
Technical data
Creation date January 24, 2020 3:24:34 PM CET
Catalogue status 13.01.2020 / We reserve the right to make technical changes. 3
Input
Number of inputs
1
Sensor Thermocouples: B / C /
E / J / K / L / N / R / S /
T / W3 / W5
- 200...+ 2300
°C depending on
thermocouple, RTD: PT10,
PT20, PT50, PT100,
PT250, PT300, PT400,
PT500, PT1000, Ni50,
Ni100, Ni120, Ni1000,
2-/3-/4-wire
Sensor supply
> 15 V DC at 20 mA
Input voltage configurable, 0(2)…10 V,
0(1)…5 V, 0…1 V DC, 0,2…
1 V DC
Input resistance, voltage
> 10 MΩ
Input current configurable, 0...20 mA,
4…20mA
Voltage drop, current input
< 3 V
Temperature input range Configurable, min.
measurement range 10°C
(RTD), min. measurement
range 50°C (TC), PT100:
-200°C…850 °C, NI100:
-60°C…+250 °C, TC type:
B (0…+1820 °C), E: (-100…
+1000 °C), J: (-100…
+1200 °C), K: (-180…
+1372 °C), L: (-200…+900
°C), N: (-180…+1300
°C), R: (-50…+1760 °C),
S: (-50…+1760 °C), T:
(-200…+400 °C), U: (-200…
+600 °C), W3: (0…+2300
°C), W5: (0…+2300 °C),
LR: (-200…+800 °C),
Details under Downloads
"Measuring range Table
ACT20M-UI-AO"
Resistance 0…10 kΩ
Potentiometer 10…100 kΩ
Output
Number of outputs
1
Output voltage, note configurable, 0(2)...10 V,
0(1)...5 V, 0(0,2)…1 V, 1…
(0,2)0 V, 5…(1)0 V, 10…
(2)0 V, downscale (0 V),
upscale (11 V), in case of
sensor error
Output current configurable, 0...20 mA,
4...20 mA, 20…0 mA, 20…
4 mA, downscale (3,5
mA), upscale (23 mA), in
case of sensor error
Cut-off frequency (-3 dB)
100 Hz
cold junction compensation internal
load impedance voltage
≥ 10 kΩ
load impedance current ≤ 600 Ω, @ max 28mA