Data Sheet

Data sheet
OMNIMATE Signal - series BLA/SLA 5.08
BLA 3 SN SW
Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 16
D-32758 Detmold
Germany
Fon: +49 5231 14-0
Fax: +49 5231 14-292083
www.weidmueller.com
Technical data
Creation date May 27, 2019 2:41:56 PM CEST
Catalogue status 23.05.2019 / We reserve the right to make technical changes. 2
Dimensions and weights
Width 15.24 mm
Width (inches) 0.6 inch
Height 15.2 mm
Height (inches) 0.598 inch
Depth 20 mm
Depth (inches)
0.787 inch
Net weight 5.48 g
system parameters
Product family OMNIMATE Signal - series
BLA/SLA 5.08
Type of connection
Field connection
Wire connection method Clamping yoke connection
Pitch in mm (P) 5.08 mm
Pitch in inches (P) 0.2 inch
Conductor outlet direction 180°
No. of poles 3
L1 in mm 10.16 mm
L1 in inches 0.4 inch
Number of rows 1
Pin series quantity 1
Rated cross-section 2.5 mm²
Touch-safe protection acc. to DIN VDE
57 106
finger-safe unplugged/
back-of-hand-safe plugged
Volume resistance
5.50 mΩ
Can be coded Yes
Stripping length 7 mm
Tightening torque, min. 0.4 Nm
Tightening torque, max. 0.5 Nm
Clamping screw M 2.5
Screwdriver blade 0.6 x 3.5
Screwdriver blade standard DIN 5264
Plugging cycles
25
Pulling force/pole, max. 2 N
Material data
Insulating material PBT GF
Colour black
Colour chart (similar) RAL 9011
Insulating material group IIIa
CTI
≥ 200
Insulation strength
≥ 10
8
Ω
UL 94 flammability rating V-0
GWFI 960 °C
Contact material CuSn
Contact surface tinned
Layer structure of plug contact 4-8 µm Sn hot-dip tinned
Storage temperature, min. -25 °C
Storage temperature, max. 55 °C
Max. relative humidity during storage 80 %
Operating temperature, min. -50 °C
Operating temperature, max. 120 °C
Temperature range, installation, min. -25 °C
Temperature range, installation, max. 120 °C
Conductors suitable for connection
Clamping range, min. 0.13 mm²
Clamping range, max. 3.32 mm²
Wire connection cross section AWG,
min. AWG 28
Wire connection cross section AWG,
max. AWG 16
Solid, min. H05(07) V-U 0.2 mm²
Solid, max. H05(07) V-U 2.5 mm²
Flexible, min. H05(07) V-K 0.2 mm²
Flexible, max. H05(07) V-K 1.5 mm²
w. plastic collar ferrule, DIN 46228 pt 4,
min. 0.2 mm²
w. plastic collar ferrule, DIN 46228 pt 4,
max. 1.5 mm²
w. wire end ferrule, DIN 46228 pt 1, min
0.2 mm²
w. wire end ferrule, DIN 46228 pt 1,
max. 1.5 mm²
Plug gauge in accordance with EN
60999 a x b; ø 2.4 mm x 1.5 mm
Max. clamping range
3.32 mm²