Technical data
Creation date February 3, 2020 9:42:54 AM CET
Catalogue status 24.01.2020 / We reserve the right to make technical changes. 2
Dimensions and weights
Length 50 mm
Length (inches) 1.969 inch
Height 50 mm
Height (inches)
1.969 inch
Net weight 75.5 g
General information
Material Polyamide 6
External thread M 40
Pitch of thread 1.5 mm
Length of thread 18 mm
AF size 1 53 mm
AF size 2 53 mm
Impact resistance 7 joules in acc. with IEC
60079-0
Protection degree IP54, IP66, IP67, IP68 - 5
bar (30 min.)
Protection degree with GWDR IP54, IP66, IP67, IP68 - 5
bar (30 min.)
Operating temperature range, min.
-60 °C
Operating temperature range, max. 70 °C
Outer cable diameter, min. 23 mm
Outer cable diameter, max. 32 mm
UL 94 flammability rating HB
Seal insert Silicone
Sealing Silicone
Tightening torque 17.5 Nm
Torque for cap nut, min. 16 Nm
Torque for cap nut, max. 19 Nm
Torque for connecting adapter, min. 16 Nm
Torque for connecting adapter, max. 19 Nm
Torque for lock nut, min. 16 Nm
Torque for lock nut, max. 19 Nm
Explosion protection type Intrinsically safe Ex i
Standards IEC 60079-0, EN 60079-0,
IEC 60079-7, EN 60079-7,
EN 60079-31, IEC
60079-31
Installation guidelines
See assembly instructions
Classifications
ETIM 6.0 EC000441
ETIM 7.0 EC000441
eClass 9.0 27-14-44-32
eClass 9.1
27-14-44-34
eClass 10.0 27-14-44-32
Approvals
Approvals CE; EAC; ATEX; IECEX; INMETRO
ROHS Conform