Datasheet

Datenblatt
A-series
A2C 4 LTGY
Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 16
D-32758 Detmold
Germany
Fon: +49 5231 1429-0
Fax: +49 5231 14292083
www.weidmueller.com
Technische Daten
Erstellungs-Datum August 8, 2017 10:39:05 AM CEST
Katalogstand 02.08.2017 / Technische Änderungen vorbehalten 3
Conductors for clamping (rated connection)
Blade size 0.6 x 3.5 mm
Clamping range, rated connection, max. 4 mm²
Clamping range, rated connection, min. 0.5 mm²
Connection direction top
Cross-section for connected conductor,
finely stranded with wire-end ferrules
and plastic collars DIN 46228/4, rated
connection, min. 0.5 mm²
Gauge to IEC 60947-1
A4
Number of connections 2
Stripping length 12 mm
Twin wire-end ferrules, max. 1 mm²
Twin wire-end ferrules, min. 0.5 mm²
Type of connection
PUSH IN
Wire connection cross section AWG,
max. AWG 12
Wire connection cross section AWG,
min.
AWG 26
Wire connection cross section, finely
stranded with wire-end ferrules DIN
46228/1, rated connection, max. 4 mm²
Wire connection cross section, finely
stranded with wire-end ferrules DIN
46228/1, rated connection, min. 0.5 mm²
Wire connection cross section, finely
stranded, max.
4 mm²
Wire connection cross section, solid
core max. rated connection 4 mm²
Wire connection cross section, solid
core, min. rated connection 0.5 mm²
Wire connection cross section, stranded,
rated connection, max. 4 mm²
Wire connection cross section, stranded,
rated connection, min. 0.5 mm²
Wire connection cross-section, finely
stranded with wire-end ferrules and
plastic collars DIN 46228/4, rated
connection, max. 4 mm²
Wire connection cross-section, finely
stranded, min.
0.5 mm²
Rating data
Rated cross-section 4 mm²
Rated voltage 800 V
Rated current 32 A
Current at maximum wires 32 A
Standards
IEC 60947-7-1
Volume resistance according to IEC
60947-7-x 1 mΩ
Rated impulse withstand voltage 8 kV
Pollution severity
3
Surge voltage category III
UL rating data
Certificate No. (cURus)
E60693
Conductor size Factory wiring max.
(cURus) 10 AWG
Conductor size Factory wiring min.
(cURus) 28 AWG
Conductor size Field wiring max. (cURus)
10 AWG
Conductor size Field wiring min. (cURus) 28 AWG
Current size B (cURus) 30 A
Current size C (cURus) 30 A
Current size D (cURus) 5 A
Voltage size B (cURus) 600 V
Voltage size C (cURus)
600 V
Voltage size D (cURus) 600 V
Classifications
ETIM 5.0 EC000897
ETIM 6.0 EC000897
eClass 6.2 27-14-11-20
eClass 7.1 27-14-11-20
eClass 8.1 27-14-11-20
eClass 9.0
27-14-11-20
eClass 9.1 27-14-11-20