Technical data
Creation date November 30, 2016 1:22:47 PM CET
Catalogue status 18.11.2016 / We reserve the right to make technical changes. 3
EMC / shock / vibration
Vibration resistance IEC 60068-2-6
2.3 g (on DIN rail), 4 g
(with direct mounting)
Interference immunity test acc. to EN 55024, EN 55022,
IEC61000-3-2,-3,
IEC61000-4-2,-3,-4,-5,-6,-8,-11
Shock resistance IEC 60068-2-27 30 g in all directions
Insulation coordination
Class of protection I, with PE connection
Humidity at operating temperature 5...95 %, no condensation
Insulation voltage input / earth 4 kV
Insulation voltage output / earth 0.5 kV
Insulation voltage, input/output 4 kV
Pollution severity
2
Surge voltage category III
Electrical safety (applied standards)
Electrical machine equipment
Acc. to EN60204
For use with electronic equipment Acc. to EN50178 /
VDE0160
Protection against dangerous shock
currents Acc. to VDE0106-101
Protective separation / protection
against electrical shock
VDE0100-410 / acc. to
DIN57100-410
Safety extra-low voltage SELV acc. to EN60950,
PELV acc. to EN60204
Safety transformers for switch-mode
power supplies Acc. to EN 61558-2-17
Connection data (input)
Conductor cross-section, AWG/kcmil ,
max. 12
Conductor cross-section, AWG/kcmil ,
min. 20
Conductor cross-section, flexible , min. 0.5 mm²
Conductor cross-section, rigid , max. 2.5 mm²
Conductor cross-section, rigid , min. 0.5 mm²
Connection system PUSH IN with actuator
Number of terminals
3 for L/N/PE
Wire connection cross section, flexible
(input), max. 2.5 mm²
Connection data (output)
Conductor cross-section, AWG/kcmil ,
max. 12
Conductor cross-section, AWG/kcmil ,
min. 26
Conductor cross-section, flexible , max. 2.5 mm²
Conductor cross-section, flexible , min. 0.2 mm²
Conductor cross-section, rigid , max. 2.5 mm²
Conductor cross-section, rigid , min. 0.2 mm²
Connection system PUSH IN with actuator
Number of terminals 5 (+ + / - - -)
Connection data (signal)
Wire connection cross-section, flexible
(signal), max. 1.5 mm²
Wire connection cross-section, flexible
(signal), min. 0.14 mm²
Wire connection method PUSH IN
Wire cross-section, AWG/kcmil , max. 16
Wire cross-section, AWG/kcmil , min. 26
Wire cross-section, solid , max.
1.5 mm²
Wire cross-section, solid , min. 0.14 mm²
Signalling
LED green/red Green: Operation (failure-
free), Flashing green:
advance warning, Flashing
green/red: Power boost,
Flashing red: overload/
error