90
1066540000/01/12.11
ACT20X-(2)HTI-(2)SAO-S
Illustration 7-27: IECEx Installation Drawing (2)
Terminal CH1 (13), CH2 (22)
Ex Input
U
o
17.4 V
I
o
18.4 mA
P
o
80 mW
L
o
/R
o
445 H/
U
i
10 V
I
i
30 mA
C
i
15 nF
L
i
1.7 µH
Group C
o
L
o
IIC 0.3 F 80 mH
IIB 1.6 F 250 mH
IIA 8 F 600 mH