Weidmüller t D Bedienungsanleitung Operating instruction IE-SW14-24-M managed Switch IE-SW8-M IE-SW6/2SCS-M IE-SW6/2SC-M IE-SW6/2ST-M IE-SW16-M IE-SW14/2SCS-M IE-SW14/2SC-M IE-SW14/2ST-M IE-SW24-M IE-SW22/2SCS-M IE-SW22/2SC-M IE-SW22/2ST-M Made in Germany 8845740000 8851850000 8845840000 8845850000 8845800000 8851860000 8845780000 8845790000 8845830000 8851870000 8845810000 8845820000
Table of content Introduction Specifications Dimensional Drawing Segment length Installation Connections Auto-MDIX LED Fault Relay Power options Management Features Declaration of conformity Warranty 12
Introduction With the new IE-SW14-24-M facility we provide up to the 24 Ethernet ports (10/100 BaseT/TX) for the control cabinet (DIN-Rail). Many applications need switches in the control cabinet for the distributed construction of industrial networks. The Switch is a Plug and Play device with ST or SC fiber connections. The devices can be operated in an ambient temperature range from 0 °C to +60 °C.
Dimensional Drawing 14
Segment Length 10 Base T copper 100 m 100 Base TX copper 100 m 100 Base FX multimode fiber 2000 m Full Duplex • connector SC and ST Halb Duplex is not supported 1310 nm/ 62.5/ 125 µm optical budget 8 db 50/ 125 µm optical budget 4 dB singlemode fiber • connector SCS 9/ 125 µm cable 13 dB Installation The IE-SW14-24-M is for wall mounting and DIN-Rail mounting.
Connections RJ-45 connector • copper • segment length up to 100 m PIN 1 2 3 4 5 6 7 8 Function TD+ TDRD+ not used not used RD-not used not used ST-connector • Multimode with 1310 nm • segment length 2000 m • full compliance with the optical performance requirements of 100 Base FX SC-connector • Multimode with 1310 nm • segment length 2000 m • full compliance with the optical performance requirements of 100 Base FX 16
Auto-MDIX The switch works with AUTO-MDIX functionality. It is possible to use crossover and straight- through cables to connect network interfaces or other devices with the switch.
Power Options In all power schemes a fuse of 4 A slow is required in the power supply lines. The IE-SW-14 to 24-M Switch does NOT charge the battery, so separate provisions charching are required. The connection to the power supply should be done by a qualified technician only. Use a Class 2 power supply only. The power supply should be conform to DIN EN 60 742 (VDE 0551) On the bottom rear end a connection to functional earth is recommended. This connection is recommended by a 4 mm² cable with a 6.
Management- Features • • • • • • • SNMP V1 Proprietary Redundancy 802.
No warranty. The technical documentation is supplied without any warranty of fitness. Weidmüller does not warrant for their accuracy. The documentation may contain technical and typographical inaccuracies. Weidmüller reserves the right to change it without notice. Keine Gewährleistung. Die technische Dokumentation wird ohne Mängelgewähr geliefert und Weidmüller übernimmt keine Gewährleistung für deren Genauigkeit.