Environmental
climatic suitability climatic class 2 '
according to VDE/VDI 3540 sheet 2
operating –25 ... +40°C '
temperature range
storage –25 ... +65°C
temperature range
relative humidity
75% annual average, non–condensing
shock resistance 15 g, 11 ms '
vibration resistance 2.5 g, 5 ... 55 Hz '
Rules and Standards
DIN 43 718 Measurement and control; front - frames and
frontpanels of measurement and control
equipment; principal dimensions
DIN 43 802 Line scales and pointers for indicating
electrical measuring instruments;
–2 general requirements
–3 designs and dimensions
–4 scale graduation and numbering
DIN 16 257 Nominal positions and position symbols used
for measuring instruments
DIN EN 60 051 Direct acting indicating analogue electrical
measuring instruments and their accessories
–1 Part 1: Definitions and general requirements
common to all parts
–2 Part 2: Special requirements for ammeters
and voltmeters
–9 Part 9: Recommended test methods
DIN EN 60 529 Enclosure codes by housings (IP- code)
DIN EN 61 010 Safety requirements for electrical measuring,
control and laboratory equipment
–1 Part 1: General requirements
–2–030 Part 2–030: Particular requirements for testing
and measuring circuits
DIN EN 61 326- 1 Electrical equipment for measurement, con -
trol and laboratory use – EMC requirements
Part 1: General requirements
DIN IEC 61 554 Panel mounted equipment –
Electrical measuring instruments –
Dimensions for panel mounting
VDE/VDI 3540 sheet 2 reliability of measuring and control
equipment (classification of climates)
Options
measuring range
special measuring deviating from ranges as specified in table
range
zero position suppressed for range 4 ... 20 mA
mechanically suppressed zero
case
window non–glaring glass
colour of bezel gray (similar to RAL 7037)
panel fixing plate springs
performance
increased mechanical shock 30 g, 11 ms
loads vibration 5 g, 5 ... 55 Hz
climatic suitability limited use in the tropics climatic class 3
according to VDE/VDI 3540 sheet 2
with operating –10 ... +55°C
temperature range
marine application non–certified
enclosure code IP 54 splash–water protected front
accessories
terminal protection against accidental contact
protective sleeves
dial
blank dial pencil marked initial and end values
scale division 0 ... 100%,
and figuring linear, full–scale values acc. to standardized
series (1 – 1.5 – 2.5 – 4 – 6 and any decimal
multiple of these numbers e.g. 150 m
3
/h) or
deviating from standard series,
captions optional
additional lettering to be specified e.g. ”generator”
additional figuring to be specified
coloured marks red, green or blue for important scale values
coloured sector red, green or blue within scale division
logo on the dial none or to be specified
Connections
+
+
movement I
movement II
Dimensions
48
41
63
72
5.5
3.5
(scaled in mm)