Ultra Boiler Manual

Part number 550-100-440/0122
139


MAINTENANCE & SPECIFICATIONS
(continued)
Figure 140 Engineering data (see Figure 141 for notes)
Boiler
Model
Ultra
Shipping
weight
Operating
weight
Water
content

per boiler
Vent/air pipe
size —
Provide a
separate vent
for each boiler
Electrical
service
required
Pounds
per boiler
Pounds
per boiler
Gallons
per boiler
GPM
@ 20°F rise
GPM
@ 40°F rise
Amps
per boiler
Note 4 Note 5 Note 6
-80
199 139 0.7 7.1 3.6 2” or 3” 15.0

207 145 0.8 9.4 4.7 2” or 3” 15.0

234 181 1.2 13.9 7.0 3” 15.0

246 192 1.6 20.7 10.4 3” or 4” 15.0

297 229 2.1 27.9 14.0 4” 15.0

297 229 2.1 36.5 18.2 4” 15.0
Figure 141 Notes for Figure 139 and Figure 140
1
Based on standard test procedures outlined by DOE for individual boilers.
Net AHRI ratings are based on piping and pickup allowance of 1.15.
Consult WM Technologies Technical Services for other allowances.
Foundation sizes in Figure139,page138 provide 6 inches between boilers and 2 inches from boiler to edge of foundation.
Smaller foundations are possible with reduced service clearances.
See page58 for details.
For side-to-side installations, see Figure56,page58.
For back-to-back installations, see Figure57,page58.
Operating weight is the total weight of the boiler, including water.
Ultra-80 and -105 vent/air pipes can be either 2” or 3” pipe. Vent/air pipe length limits for 2” piping are not as long as for 3” piping.
Ultra-230 vent/air pipes can be either 3” or 4” pipe. Vent/air pipe length limits for 3” piping are not as long as for 4” piping.
All Ultra installations require a separate vent pipe and termination for each boiler.
Vent piping cannot be manifolded. Install and
terminate vents as described in vent/air installation instructions in this manual.
Combustion air piping can be individually piped or manifolded. See Figure59,page59, for manifolded air piping.
6
Total amp requirement includes up to three circulators, not exceeding 2.2 amps per circulator.